Replacing A Hot-Swap Fan Assembly - IBM System x3750 M4 Type 8722 Installation And Service Manual

Hide thumbs Also See for System x3750 M4 Type 8722:
Table of Contents

Advertisement

Replacing a hot-swap fan assembly

The server comes standard with six speed-controlled hot-swap cooling fans.
Attention: To ensure proper operation, replace a failed hot-swap fan within 30
seconds.
To install or replace a hot-swap fan, complete the following steps:
1. Touch the static-protective package that contains the new fan to any unpainted
2. Orient the fan over the fan slot in the fan cage assembly so that the fan
3. Insert the fan into the fan slot in the fan cage assembly and ensure that is it
4. Install the cover (see "Replacing the server top cover" on page 207).
5. Slide the server into the rack.
244
System x3750 M4 Types 8722 and 8733: Installation and Service Guide
metal surface on the server. Then, remove the new fan from the package.
connector aligns with the connector on the system board.
Hot-swap fan
Hot-swap
fan error LED
seated correctly and the fan release tab is in the slot (hole) on the fan cage
assembly.
Fan latch

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3750 m4 type 8733