IBM System x3750 M4 Type 8722 Installation And Service Manual page 413

Hide thumbs Also See for System x3750 M4 Type 8722:
Table of Contents

Advertisement

80010202-2801ffff
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: The CMOS battery voltage has dropped below its specified threshold.
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 1
Automatically notify Support: Yes
User response: Replace the CMOS battery.
80010204-1d01ffff
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: IMM has detected the speed of Fan 1 (Fan 1A Tach or Fan 1B Tach) has gone low.
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
Reseat the failing fan indicated by the lit LED on the fan.
v
Replace Fan.
v
80010204-1d02ffff
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: IMM has detected the speed of Fan 2 (Fan 2A Tach or Fan 2B Tach) has gone low.
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
Reseat the failing fan indicated by the lit LED on the fan.
v
Replace Fan.
v
80010202-2801ffff • 80010204-1d02ffff
Appendix D. Integrated management module II (IMM2) error messages
397

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3750 m4 type 8733

Table of Contents