80010901-140cffff • 80010901-2d01ffff
80010901-140cffff
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
Explanation: IMM has detected that the temperature of a microprocessor and memory expansion tray voltage
regulator has risen above the upper critical threshold.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80010901-2701ffff
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
Explanation: IMM has detected that the ambient temperature has risen above its upper critical threshold.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80010901-2d01ffff
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
Explanation: The PCH temperature sensor has risen above its upper critical threshold. A soft shutdown will be
attempted.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.