Sign In
Upload
Manuals
Brands
Primes Manuals
Monitor
CPM C-9
Primes CPM C-9 Laser Power Monitor Manuals
Manuals and User Guides for Primes CPM C-9 Laser Power Monitor. We have
2
Primes CPM C-9 Laser Power Monitor manuals available for free PDF download: Original Operating Manual, Operating Manual
Primes CPM C-9 Original Operating Manual (94 pages)
Brand:
Primes
| Category:
Measuring Instruments
| Size: 6 MB
Table of Contents
Read Carefully before Use
3
Table of Contents
4
Basic Safety Notes
8
Intended Use
8
Conversions and Modifications
9
Liability Disclaimer
9
Icons and Conventions
9
Product Safety Labels
10
About this Operating Manual
11
Device Description
12
Type Overview
12
Devices with Turbine
12
Devices with Oval Wheel Meter
13
Functional Description
13
Measuring Principle
13
Tara Button
14
Tare Function
14
Switching between the Screens of the Display
14
Optical Displays and Acoustic Signal
14
Leds
14
Display
14
Acoustic Warning Signal
16
Explanation of the Product Safety Labels and Warning Labels
16
Scope of Delivery and Optional Accessories
17
Transport and Storage
18
Warning Messages
18
Shipping the Device with Permanently Installed Lithium Metal Batteries
19
Mounting
20
Conditions at the Installation Site
20
Installation in the Laser System
20
Prepare Mounting
20
Possible Mounting Positions
20
Align the Device
22
Mount the Device
23
Removal from the Laser System
28
Connectors
29
Overview of Connectors
29
Power Supply
29
Power Supply Via PRIMES Power Supply When Used as a Stand-Alone Device
30
Power Supply Via USB or PRIMES Power Supply and Communication with the PC Via USB
31
Power Supply Via PRIMES Power Supply and Communication with the PC Via PRIMES Converter
32
Required Components
32
PRIMES Bus RS485
34
Pin Assignment
34
Usb
34
Specification
34
Installing the USB Driver Manually
35
Analog out
36
Safety Interlock (Interlock)
37
Cooling Circuit (Water In/ Water Out)
38
Connect/Remove Cooling Water Hoses
38
Damage to the Device
38
Water Quality
38
Avoid Measurement Inaccuracies
39
Damage to the Flow Meter
40
Parameters of Cooling Water Connection
41
Pressure Loss
42
Software Installation
44
Install Laserdiagnosticssoftware LDS
44
Install Powermonitorsoftware PMS
45
Measuring
46
Warning Messages
46
Preparing Measurement Readiness
47
Measuring with the CPM as a Stand-Alone Device
47
Start Measurement
47
Measuring with the Laserdiagnosticssoftware LDS
48
Connect/Disconnect the Device with the LDS
48
General Information about Working with the LDS
49
Saving Options
49
Open Power Measurement Mode
50
Perform Power Measurement
50
Measurement Results Display
52
Measuring with the Powermonitorsoftware PMS
53
Switch on Device and Start PMS
53
Connect Device with the PMS
54
Testing the Interface
55
Testing the Communication of Multiple Devices
56
Determine Device Offset
57
Perform Power Measurement
58
Measuring Value Display
59
Status Window
60
Troubleshooting
61
Messages in the LDS During Measurement
61
Connection Error with the LDS
62
Acoustic Warning Signal
62
Warning or Error Message on the Display
63
Warning Message (Warning Triangle on the Display)
63
Other Errors
64
Error Message (Warning Triangle on the Display and Error LED Lights up Red)
64
Damages to the Absorber
65
Maintenance and Service
67
Maintenance Intervals
67
Cleaning the Device Surface
67
Measures for the Product Disposal
68
Declaration of Conformity
69
Technical Data
70
Cpm F-1, Cpm F-10, Cpm F-20, Cpm F-30
70
Cpm C-9
72
Dimensions
74
Cpm F-1
74
Cpm F-10
75
Cpm F-20
76
Cpm F-30
77
Cpm C-9
78
CPM F-1 with Oval Wheel Meter
79
CPM F-10 with Oval Wheel Meter
80
CPM F-20 with Oval Wheel Meter
82
Appendix
84
A Diagrams of the Max. Laser Power as a Function of the Beam Diameter
84
BGNU GPL License Notice
86
C Operation of the CPM with a PRIMES Paneldisplay
87
D Fiber Adapters and Domes
89
E Parallel Operation of the CPM with a Focusmonitor FM
94
Advertisement
Primes CPM C-9 Operating Manual (58 pages)
LaserDiagnosticsSoftware LDS, PowerMonitorSoftware PMS
Brand:
Primes
| Category:
Monitor
| Size: 2 MB
Table of Contents
Table of Contents
4
1 Basic Safety Instructions
7
2 Symbol Explanations
9
3 About this Operating Manual
10
4 Conditions at the Installation Site
10
5 Introduction
10
System Description
10
Measuring Principle
10
Overview of the Compactpowermonitor CPM Types
11
Connection Overview
12
Short Overview Installation
13
6 Transport
14
7 Installation
15
Preparation
15
Installation Position
15
Align the Compactpowermonitor CPM
15
Install the Compactpowermonitor CPM
16
Remove the Compactpowermonitor CPM
19
8 Connect Cooling Circuit
20
Water Quality
20
Water Pressure
20
Humidity
21
Temperature Fluctuations of the Inflowing Cooling Water
22
Flow Rate
22
Connect Hoses
23
9 Electrical Connection
24
Power Supply
24
PRIMES Bus
24
Connect the Safety Interlock
25
Connecting the PC Via the USB Interface
26
Scope of Delivery
26
Connect PC
26
Install the USB Driver Manually
27
Connecting the PC Via RS232 Interface and Optional PRIMES Converter
28
Scope of Delivery
28
Connect PC
28
Parallel Operation of the Compactpowermonitor PMC And, for Example, the Focusmonitor FM
30
Analog Output
31
10 Display, Control Elements and Audible Signals
32
Measured Value Display
32
Status Display
32
External Display (Option)
33
Control Elements
33
Audible Signals
33
11 Measuring with the Optional Laserdiagnosticssoftware LDS
34
Safety Instructions
34
Getting Ready for Operation
35
Perform Power Measurement
35
Connect the Compactpowermonitor CPM with the Laserdiagnosticssoftware LDS
35
Choose Power Measurement Mode
36
Configure Settings (Device Control)
36
Starting a Power Measurement
37
Measurement Results Display
37
12 Install the Powermonitorsoftware PMS
38
Start Software and Select Operating Mode
38
For Connection Via the RS232 and PRIMES Converter
38
For Connection Via the USB Interface
38
Testing the Interface
39
Testing the Communication of Multiple Devices
40
13 Measuring with the Powermonitor Software PMS
41
Safety Instructions
41
Getting Ready for Operation
42
Starting the Software
42
Perform Power Measurement
42
The Graphical User Interface of the Powermonitor Software PMS
43
Measuring Value Display
44
Window a (Numerical Display)
44
Window B (Graphical Display)
45
Status Window
45
14 Storage
46
15 Maintenance and Service
46
16 Measures for the Product Disposal
46
17 Declaration of Conformity
47
18 Technical Data
48
Cpm C-9
48
Cpm F-1, Cpm F-10, Cpm F-20, Cpm F-30
49
19 Dimensions
50
Dimensions CPM C-9
50
Dimensions CPM F-1
51
Dimensions CPM F-10
52
Dimensions CPM F-20
53
Dimensions CPM F-30
54
20 Appendix
55
Operation of the Compactpowermonitor with Paneldisplay (Without PC)
55
Pin Assignment 9-Pole D-Sub Socket
56
Measurement Display
56
Mounting Position of a Compactpowermonitor CPM with Oval Wheel Meter
57
Accessories Fiber Adapter
58
Advertisement
Related Products
Primes CompactPowerMonitor Series
Primes CPM F-10
Primes CPM F-20
Primes CPM F-30
Primes CPM F-1
Primes Cube M
Primes CUBE
Primes Cube L
Primes CompactPowerMonitor CPM+
Primes Cube XT
Primes Categories
Measuring Instruments
Diagnostic Equipment
Monitor
More Primes Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL