Remove the CompactPowerMonitor CPM

1. First of all turn the the laser source off.
2. Turn off the voltage supply.
3. Ensure that moving parts, e.g. robot arms, etc. are at a standstill and that they cannot be set in motion
unintentionally.
4. Switch the cooling curcuit off.
5. Remove all connection cables and hoses of the cooling circuit.
6. Remove the device.
NOTICE
Damaging/Destruction of the flow rate meter
The flow rate meter is not designated for high rotational speed.
X Do not use compressed air for emptying the cooling circuit.
7. Empty the cooling circuit completely and seal the connector plugs by means of the enclosed sealing
plugs.