Sign In
Upload
Manuals
Brands
Agilent Technologies Manuals
Test Equipment
InfiniiVision DSO7104A
Agilent Technologies InfiniiVision DSO7104A Manuals
Manuals and User Guides for Agilent Technologies InfiniiVision DSO7104A. We have
2
Agilent Technologies InfiniiVision DSO7104A manuals available for free PDF download: Programmer's Manual, User Manual
Agilent Technologies InfiniiVision DSO7104A Programmer's Manual (922 pages)
Brand:
Agilent Technologies
| Category:
Test Equipment
| Size: 5.3 MB
Table of Contents
In this Book
3
Table of Contents
5
1 What's New
22
What's New in Version 6.00
22
What's New in Version
25
What's New in Version
27
What's New in Version
30
What's New in Version
32
Version 5.00 at Introduction
33
2 Setting up
35
Step 1. Install Agilent IO Libraries Suite Software
36
Step 2. Connect and Set up the Oscilloscope
37
Using the USB (Device) Interface
37
Using the LAN Interface
37
Step 3. Verify the Oscilloscope Connection
39
3 Getting Started
45
Basic Oscilloscope Program Structure
46
Initializing
46
Capturing Data
46
Analyzing Captured Data
47
Programming the Oscilloscope
48
Referencing the IO Library
48
Opening the Oscilloscope Connection Via the IO Library
49
Initializing the Interface and the Oscilloscope
49
Getting Started
49
Using :Autoscale to Automate Oscilloscope Setup
50
Using Other Oscilloscope Setup Commands
50
Capturing Data with the :Digitize Command
51
Reading Query Responses from the Oscilloscope
53
Reading Query Results into String Variables
54
Reading Query Results into Numeric Variables
54
Reading Definite-Length Block Query Response Data
54
Reading Definite- Length Block Query Response Data
54
Sending Multiple Queries and Reading Results
55
Checking Instrument Status
56
Other Ways of Sending Commands
57
Telnet Sockets
57
Sending SCPI Commands Using Browser Web Control
57
4 Commands Quick Reference
59
Command Summary
60
Syntax Elements
108
Number Format
108
Line Terminator)
108
] (Optional Syntax Terms)
108
(Braces)
108
(Defined As)
108
(Angle Brackets)
109
(Ellipsis)
109
D (Digits)
109
Quoted ASCII String
109
Definite-Length Block Response Data
109
5 Commands by Subsystem
111
Common (*) Commands
113
CLS (Clear Status)
117
ESE (Standard Event Status Enable)
118
ESR (Standard Event Status Register)
120
IDN (Identification Number)
122
LRN (Learn Device Setup)
123
OPC (Operation Complete)
124
OPT (Option Identification)
125
RCL (Recall)
127
RST (Reset)
128
SAV (Save)
131
SRE (Service Request Enable)
132
STB (Read Status Byte)
134
TRG (Trigger)
136
TST (Self Test)
137
WAI (Wait to Continue)
138
Root (:) Commands
139
Activity
142
AER (Arm Event Register)
143
Autoscale
144
Autoscale:amode
146
Autoscale:channels
147
Blank
148
Cdisplay
149
Digitize
150
Hweenable (Hardware Event Enable Register)
152
Hweregister:condition (Hardware Event Condition Register)
154
Hweregister[:Event] (Hardware Event Event Register)
156
Merge
158
Mteenable (Mask Test Event Enable Register)
159
Mteregister[:Event] (Mask Test Event Event Register)
161
OPEE (Operation Status Enable Register)
163
Operegister:condition (Operation Status Condition Register)
165
Operegister[:Event] (Operation Status Event Register)
167
Ovlenable (Overload Event Enable Register)
169
Ovlregister (Overload Event Register)
171
Print
173
Run
174
Serial
175
Single
176
Status
177
Stop
178
TER (Trigger Event Register)
179
View
180
Acquire Commands
181
Acquire:aalias
183
Acquire:complete
184
Acquire:count
185
Acquire:daalias
186
Acquire:mode
187
Acquire:points
188
Acquire:rsignal
189
Acquire:segmented:analyze
190
Acquire:segmented:count
191
Acquire:segmented:index
192
Acquire:srate
195
Acquire:type
196
Bus<N> Commands
198
Bus<N>:Bit<M
200
Bus<N>:Bits
201
Bus<N>:Clear
203
Bus<N>:Display
204
Bus<N>:Label
205
Bus<N>:Mask
206
Calibrate Commands
207
Calibrate:date
209
Calibrate:label
210
Calibrate:output
211
Calibrate:start
212
Calibrate:status
213
Calibrate:switch
214
Calibrate:temperature
215
Calibrate:time
216
Channel<N> Commands
217
Channel<N>:Bwlimit
220
Channel<N>:Coupling
221
Channel<N>:Display
222
Channel<N>:Impedance
223
Channel<N>:Invert
224
Channel<N>:Label
225
Channel<N>:Offset
226
Channel<N>:Probe
227
Channel<N>:Probe:head[:Type]
228
Channel<N>:Probe:ID
229
Channel<N>:Probe:skew
230
Channel<N>:Probe:stype
231
Channel<N>:Protection
232
Channel<N>:Range
233
Channel<N>:Scale
234
Channel<N>:Units
235
Channel<N>:Vernier
236
Digital<N> Commands
237
Digital<N>:Display
239
Digital<N>:Label
240
Digital<N>:Position
241
Digital<N>:Size
242
Digital<N>:Threshold
243
Display Commands
244
Display:clear
246
Display:data
247
Display:label
249
Display:lablist
250
Display:persistence
251
Display:source
252
Display:vectors
253
External Trigger Commands
254
External:bwlimit
256
External:impedance
257
External:probe
258
External:probe:ID
259
External:probe:stype
260
External:protection
261
External:range
262
External:units
263
Function Commands
264
Function:center
267
Function:display
268
Function:goft:operation
269
Function:goft:source1
270
Function:goft:source2
271
Function:offset
272
Function:operation
273
Function:range
274
Function:reference
275
Function:scale
276
Function:source1
277
Function:source2
278
Function:span
279
Function:window
280
Hardcopy Commands
281
Hardcopy:area
283
Hardcopy:aprinter
284
Hardcopy:factors
285
Hardcopy:ffeed
286
Hardcopy:inksaver
287
Hardcopy:layout
288
Hardcopy:palette
289
Hardcopy:printer:list
290
Hardcopy:start
291
Lister Commands
292
Lister:data
293
Lister:display
294
Marker Commands
295
Marker:mode
297
Marker:x1Position
298
Marker:x1Y1Source
299
Marker:x2Position
300
Marker:x2Y2Source
301
Marker:xdelta
302
Marker:y1Position
303
Marker:y2Position
304
Marker:ydelta
305
Measure Commands
306
Measure:clear
314
Measure:counter
315
Measure:define
316
Measure:delay
319
Measure:dutycycle
321
Measure:falltime
322
Measure:frequency
323
Measure:nwidth
324
Measure:overshoot
325
Measure:period
327
Measure:phase
328
Measure:preshoot
329
Measure:pwidth
330
Measure:results
331
Measure:risetime
334
Measure:sdeviation
335
Measure:show
336
Measure:source
337
Measure:statistics
339
Measure:statistics:increment
340
Measure:statistics:reset
341
Measure:tedge
342
Measure:tvalue
344
Measure:vamplitude
346
Measure:vaverage
347
Measure:vbase
348
Measure:vmax
349
Measure:vmin
350
Measure:vpp
351
Measure:vratio
352
Measure:vrms
353
Measure:vtime
354
Measure:vtop
355
Measure:xmax
356
Measure:xmin
357
Mtest Commands
358
Mtest:amask:create
363
Mtest:amask:source
364
Mtest:amask:units
365
Mtest:amask:xdelta
366
Mtest:amask:ydelta
367
Mtest:count:fwaveforms
368
Mtest:count:reset
369
Mtest:count:time
370
Mtest:count:waveforms
371
Mtest:data
372
Mtest:delete
373
Mtest:enable
374
Mtest:lock
375
Mtest:output
376
Mtest:rmode
377
Mtest:rmode:faction:measure
378
Mtest:rmode:faction:print
379
Mtest:rmode:faction:save
380
Mtest:rmode:faction:stop
381
Mtest:rmode:sigma
382
Mtest:rmode:time
383
Mtest:rmode:waveforms
384
Mtest:scale:bind
385
Mtest:scale:x1
386
Mtest:scale:xdelta
387
Mtest:scale:y1
388
Mtest:scale:y2
389
Mtest:source
390
Mtest:title
391
POD Commands
392
Pod<N>:Display
393
Pod<N>:Size
394
Pod<N>:Threshold
395
Recall Commands
397
Recall:filename
398
Recall:image[:Start]
399
Recall:mask[:Start]
400
Recall:pwd
401
Recall:setup[:Start]
402
SAVE Commands
403
Save:filename
405
Save:image[:Start]
406
Save:image:area
407
Save:image:factors
408
Save:image:format
409
Save:image:inksaver
410
Save:image:palette
411
Save:lister[:Start]
412
Save:mask[:Start]
413
Save:pwd
414
Save:setup[:Start]
415
Save:waveform[:Start]
416
Save:waveform:format
417
Save:waveform:length
418
Save:waveform:segmented
419
SBUS Commands
420
Sbus:can:count:error
422
Sbus:can:count:overload
423
Sbus:can:count:reset
424
Sbus:can:count:total
425
Sbus:can:count:utilization
426
Sbus:display
427
Sbus:flexray:count:null
428
Sbus:flexray:count:reset
429
Sbus:flexray:count:sync
430
Sbus:flexray:count:total
431
Sbus:i2S:base
432
Sbus:IIC:asize
433
Sbus:lin:parity
434
Sbus:m1553:Base
435
Sbus:mode
436
Sbus:spi:bitorder
437
Sbus:spi:width
438
Sbus:uart:base
439
Sbus:uart:count:error
440
Sbus:uart:count:reset
441
Sbus:uart:count:rxframes
442
Sbus:uart:count:txframes
443
Sbus:uart:framing
444
System Commands
445
System:date
446
System:dsp
447
System:error
448
System:lock
449
System:precision
450
System:protection:lock
451
System:setup
452
System:time
454
Timebase Commands
455
Timebase:mode
457
Timebase:position
458
Timebase:range
459
Timebase:refclock
460
Timebase:reference
461
Timebase:scale
462
Timebase:vernier
463
Timebase:window:position
464
Timebase:window:range
465
Timebase:window:scale
466
Trigger Commands
467
General :Trigger Commands
470
Trigger:hfreject
471
Trigger:holdoff
472
Trigger:mode
473
Trigger:nreject
474
Trigger:pattern
475
Trigger:sweep
477
Trigger:can Commands
478
Trigger:can:pattern:data
480
Trigger:can:pattern:data:length
481
Trigger:can:pattern:ID
482
Trigger:can:pattern:ID:mode
483
Trigger:can:samplepoint
484
Trigger:can:signal:baudrate
485
Trigger:can:source
486
Trigger:can:trigger
487
Trigger:duration Commands
489
Trigger:duration:greaterthan
490
Trigger:duration:lessthan
491
Trigger:duration:pattern
492
Trigger:duration:qualifier
493
Trigger:duration:range
494
Trigger:eburst Commands
495
Trigger:eburst:count
496
Trigger:eburst:idle
497
Trigger:eburst:slope
498
Trigger[:Edge] Commands
499
Trigger[:Edge]:Coupling
500
Trigger[:Edge]:Level
501
Trigger[:Edge]:Reject
502
Trigger[:Edge]:Slope
503
Trigger[:Edge]:Source
504
Trigger:flexray Commands
505
Trigger:flexray:autosetup
506
Trigger:flexray:baudrate
507
Trigger:flexray:channel
508
Trigger:flexray:error:type
509
Trigger:flexray:event:type
510
Trigger:flexray:frame:ccbase
511
Trigger:flexray:frame:ccrepetition
512
Trigger:flexray:frame:ID
513
Trigger:flexray:frame:type
514
Trigger:flexray:source
515
Trigger:flexray:trigger
516
Trigger:glitch Commands
517
Trigger:glitch:greaterthan
519
Trigger:glitch:lessthan
520
Trigger:glitch:level
521
Trigger:glitch:polarity
522
Trigger:glitch:qualifier
523
Trigger:glitch:range
524
Trigger:glitch:source
525
Trigger:i2S Commands
526
Trigger:i2S:alignment
528
Trigger:i2S:audio
529
Trigger:i2S:clock:slope
530
Trigger:i2S:pattern:data
531
Trigger:i2S:pattern:format
533
Trigger:i2S:range
534
Trigger:i2S:rwidth
536
Trigger:i2S:source:clock
537
Trigger:i2S:source:data
538
Trigger:i2S:source:wselect
539
Trigger:i2S:trigger
540
Trigger:i2S:twidth
542
Trigger:i2S:wslow
543
Trigger:IIC Commands
544
Trigger:IIC:pattern:address
545
Trigger:IIC:pattern:data
546
Trigger:IIC:pattern:data2
547
Trigger:IIC[:Source]:Clock
548
Trigger:IIC[:Source]:Data
549
Trigger:IIC:trigger:qualifier
550
Trigger:IIC:trigger[:Type]
551
Trigger:lin Commands
553
Trigger:lin:ID
555
Trigger:lin:pattern:data
556
Trigger:lin:pattern:data:length
558
Trigger:lin:pattern:format
559
Trigger:lin:samplepoint
560
Trigger:lin:signal:baudrate
561
Trigger:lin:source
562
Trigger:lin:standard
563
Trigger:lin:syncbreak
564
Trigger:lin:trigger
565
Trigger:m1553 Commands
566
Trigger:m1553:Autosetup
567
Trigger:m1553:Pattern:data
568
Trigger:m1553:Rta
569
Trigger:m1553:Source:lower
570
Trigger:m1553:Source:upper
571
Trigger:m1553:Type
572
Trigger:sequence Commands
573
Trigger:sequence:count
574
Trigger:sequence:edge
575
Trigger:sequence:find
576
Trigger:sequence:pattern
577
Trigger:sequence:reset
578
Trigger:sequence:timer
579
Trigger:sequence:trigger
580
Trigger:spi Commands
581
Trigger:spi:clock:slope
582
Trigger:spi:clock:timeout
583
Trigger:spi:framing
584
Trigger:spi:pattern:data
585
Trigger:spi:pattern:width
586
Trigger:spi:source:clock
587
Trigger:spi:source:data
588
Trigger:spi:source:frame
589
Trigger:tv Commands
590
Trigger:tv:line
591
Trigger:tv:mode
592
Trigger:tv:polarity
593
Trigger:tv:source
594
Trigger:tv:standard
595
Trigger:uart Commands
596
Trigger:uart:base
598
Trigger:uart:baudrate
599
Trigger:uart:bitorder
600
Trigger:uart:burst
601
Trigger:uart:data
602
Trigger:uart:idle
603
Trigger:uart:parity
604
Trigger:uart:polarity
605
Trigger:uart:qualifier
606
Trigger:uart:source:rx
607
Trigger:uart:source:tx
608
Trigger:uart:type
609
Trigger:uart:width
610
Trigger:usb Commands
611
Trigger:usb:source:dminus
612
Trigger:usb:source:dplus
613
Trigger:usb:speed
614
Trigger:usb:trigger
615
Waveform Commands
616
Waveform:byteorder
624
Waveform:count
625
Waveform:data
626
Waveform:format
628
Waveform:points
629
Waveform:points:mode
631
Waveform:preamble
633
Waveform:segmented:count
636
Waveform:segmented:ttag
637
Waveform:source
638
Waveform:source:subsource
642
Waveform:type
643
Waveform:unsigned
644
Waveform:view
645
Waveform:xincrement
646
Waveform:xorigin
647
Waveform:xreference
648
Waveform:yincrement
649
Waveform:yorigin
650
Waveform:yreference
651
6 Commands A-Z
653
7 Obsolete and Discontinued Commands
687
Channel:activity
693
Channel:label
694
Channel:threshold
695
Channel2:Skew
696
Channel<N>:Input
697
Channel<N>:Pmode
698
Display:connect
699
Display:order
700
Erase
701
External:input
702
External:pmode
703
Function:source
704
Function:view
705
Hardcopy:destination
706
Hardcopy:device
707
Hardcopy:filename
708
Hardcopy:format
709
Hardcopy:grayscale
710
Hardcopy:igcolors
711
Hardcopy:pdriver
712
Measure:lower
713
Measure:scratch
714
Measure:tdelta
715
Measure:thresholds
716
Measure:tmax
717
Measure:tmin
718
Measure:tstart
719
Measure:tstop
720
Measure:tvolt
721
Measure:upper
723
Measure:vdelta
724
Measure:vstart
725
Measure:vstop
726
Mtest:amask:{Save | Store
727
Mtest:average
728
Mtest:average:count
729
Mtest:load
730
Mtest:rumode
731
Mtest:rumode:sofailure
732
Mtest:{Start | STOP
733
Mtest:trigger:source
734
Print
735
Timebase:delay
737
Trigger:can:acknowledge
738
Trigger:can:signal:definition
739
Trigger:lin:signal:definition
740
Trigger:threshold
741
Trigger:tv:tvmode
742
8 Error Messages
751
9 Status Reporting
751
Status Reporting Data Structures
754
Status Byte Register (STB)
757
Service Request Enable Register (SRE)
759
Trigger Event Register (TER)
760
Output Queue
761
Message Queue
762
(Standard) Event Status Register (ESR)
763
(Standard) Event Status Enable Register (ESE)
764
Error Queue
765
Operation Status Event Register (:Operegister[:Event])
766
Operation Status Condition Register (:Operegister:condition)
767
Arm Event Register (AER)
768
Overload Event Register (:Ovlregister)
769
Hardware Event Event Register (:Hweregister[:Event])
770
Hardware Event Condition Register (:Hweregister:condition)
771
Mask Test Event Event Register (:Mteregister[:Event])
772
Clearing Registers and Queues
773
Status Reporting Decision Chart
774
10 Synchronizing Acquisitions
775
Synchronization in the Programming Flow
776
Set up the Oscilloscope
776
Acquire a Waveform
776
Retrieve Results
776
Blocking Synchronization
777
Polling Synchronization with Timeout
778
Synchronizing with a Single-Shot Device under Test (DUT)
780
Synchronization with an Averaging Acquisition
782
Advertisement
Agilent Technologies InfiniiVision DSO7104A User Manual (428 pages)
InfiniiVision 5000/6000/7000 Series Oscilloscopes
Brand:
Agilent Technologies
| Category:
Test Equipment
| Size: 14.38 MB
Table of Contents
Safety Notices
2
Book Map
3
In this User's Guide
4
Table of Contents
7
Introduction
21
Models Covered in this Manual
22
Specifications and Characteristics
23
Licensed Options
24
Notes
26
Initial Setup
27
Package Contents
28
5000 Series Oscilloscope Package Contents
29
6000A Series Oscilloscope Package Contents
30
6000A Option BAT Oscilloscope Package Contents
31
6000L Series Oscilloscope Package Contents
32
7000A Series Oscilloscope Package Contents
33
Accessories Available
34
Tilt the Oscilloscope up for Easy Viewing
36
To Tilt the 5000 Series Oscilloscope up for Easy Viewing
36
To Tilt the 6000 Series Oscilloscope up for Easy Viewing
37
To Tilt the 7000 Series Oscilloscope up for Easy Viewing
38
To Install the Optional Front Panel Overlay
40
5000 Series Overlay
40
6000 Series Overlay
41
7000 Series Overlay
42
To Mount the Oscilloscope in a Rack
43
To Mount the 5000 or 6000 Series Oscilloscope in a Rack
43
To Mount the 6000L Series Oscilloscope in a Rack
43
To Mount the 7000 Series Oscilloscope in a Rack
46
Ventilation Requirements
47
5000 And 6000A Series Ventilation Requirements
47
6000L Series Ventilation Requirements
47
7000 Series Ventilation Requirements
47
Power Requirements
48
Power-On the 5000/6000/7000 Series Oscilloscope
49
Power-On the Battery-Powered 6000A Series Oscilloscope
49
Caution Indicator
50
AC Adapter for Battery-Powered Oscilloscopes
52
Keys, Softkeys, and the Entry Knob
53
Verifying Basic Oscilloscope Operation
54
Quick Help
55
Quick Help Languages
56
Graphical User Interface Languages
56
Quick Help Updates
56
To Set the Clock
57
To Set up the Screen Saver
58
Using the Analog Channels
59
To Set up the Horizontal Time Base
64
Connecting to the Device under Test
71
Analog Input Impedance (50 Ohm or 1 Mohm)
72
Autoprobe Interface
72
Passive Probes
73
Active Probes
74
Active Probes for 6000 Series 100 Mhz Bandwidth Models
75
Connect the Probes to the Oscilloscope
75
Maximum Input Voltage at Analog Inputs
76
Do Not Float the Oscilloscope Chassis
76
Compensating Passive Probes
77
Calibrating Probes
78
Manually Setting the Probe Attenuation Factor
80
Digital Probes
80
Triggering
81
Triggering - General Information
83
Trigger Mode and Coupling Menu
84
Auto and Normal Trigger Modes
84
Choosing Auto Trigger Mode or Normal Trigger Mode
84
Auto Mode
85
Normal Mode
85
Trigger Level Adjustment
86
Trigger Coupling
87
Trigger Noise Rejection
87
HF Reject
88
LF Reject
89
Noise Rejection
89
Trigger Holdoff
90
Trigger Holdoff Operating Hints
90
To Set Holdoff
90
External Trigger Input
92
2-Channel Oscilloscope External Trigger Input
92
Maximum Voltage at 2-Channel Oscilloscope External Trigger Input
93
4-Channel Oscilloscope External Trigger Input
94
Maximum Voltage at 4-Channel Oscilloscope External Trigger Input
94
Trigger Output
95
Triggers
95
Source Frequency
95
Source Frequency/8
95
Trigger Types
96
CAN Trigger
98
Duration Trigger
102
Qualifier Time Set Softkey
103
Edge Trigger
105
Flexray Setup and Triggering
107
Setup for Flexray Signals
107
Flexray Triggering
108
Glitch or Narrow Pulse Capture
112
Using Peak Detect Mode to Find a Glitch
113
I2C Trigger
115
I2S Trigger
121
LIN Trigger
128
MIL-STD 1553 Setup and Triggering
131
Probing MIL-STD 1553 Signals
131
Setup for MIL-STD 1553 Signals
132
MIL-STD 1553 Triggering
133
Nth Edge Burst Trigger
135
Pattern Trigger
137
Hex Bus Pattern Trigger
139
Pulse Width Trigger
140
Qualifier Time Set Softkey
141
Qualifier Time Set Softkey
142
Sequence Trigger
143
Define the "Find" Stage
145
Define the "Trigger On" Stage
146
Define the Optional "Reset On" Stage
147
Adjust the Trigger Level
149
SPI Trigger
150
Assign Oscilloscope Channels to SPI Signals
151
Set up the Bits in the Serial Data String
155
Resetting All Bits in the Serial Data String to One Value
155
TV Trigger
156
TV Triggering Examples
159
To Trigger on a Specific Line of Video
160
To Trigger on All Sync Pulses
161
To Trigger on a Specific Field of the Video Signal
161
To Trigger on All Fields of the Video Signal
162
To Trigger on Odd or Even Fields
163
UART/RS232 Trigger
166
USB Trigger
170
Displaying
173
Tips for Displaying Waveforms
174
Stabilizing the Display
174
Interpreting the Display
175
Graphic Symbols in Softkey Menus
176
Autoscale
177
How Autoscale Works
177
Undo Autoscale
177
Enabling Fast Debug Autoscale
178
Specifying the Channels Displayed after Autoscale
178
Preserving the Acquisition Mode During Autoscale
178
Pan and Zoom
179
Waveform Intensity and Signal Detail
180
Grid Intensity
181
Infinite Persistence
182
Using Labels
183
Waveform Expansion Reference Point
187
Vectors (Connect the Dots)
187
Freeze Display
188
Antialiasing
189
XGA Video Output
189
Measurements and Math Functions
191
List of Automatic Measurements
192
Making Automatic Measurements
193
Measurement Statistics
194
Measurement Thresholds
197
Measurement Definitions
199
Time Measurements
199
Delay and Phase Measurements
203
Voltage Measurements
205
Overshoot and Preshoot Measurements
211
Cursor Measurements
214
To Make Cursor Measurements
215
Cursor Examples
217
XY Horizontal Mode
220
Math Functions
224
To Use Waveform Math
224
To Perform a Math Function Upon an Arithmetic Operation
225
Math Scale and Offset
225
Units
226
Multiply
227
Add or Subtract
228
Differentiate
230
Integrate
232
Square Root
234
FFT Measurement
236
FFT Operation
238
Enabling Precision Measurements and Math
242
Printing and Saving
243
Printing the Oscilloscope's Display
244
Quick Print
244
To Print the Oscilloscope's Display
245
Options
245
Palette
246
Saving Oscilloscope Data
247
Selecting a Destination for Your Saved Data
248
Selecting a File Name
249
Saving Waveform Trace and Oscilloscope Setup
250
Display Image and Waveform Data File Formats
250
Choosing Save Settings
251
To Save a Waveform And/Or Setup to a USB Mass Storage Device
255
To Save a Waveform And/Or Setup to the Oscilloscope's Internal Memory
256
To Recall Waveform Trace And/Or Oscilloscope Setup
256
File Explorer
257
Acquisition Modes
261
To Start and Stop an Acquisition
262
To Make a Single Acquisition
264
Acquisition Modes
265
At Slower Sweep Speeds
265
Selecting the Acquisition Mode
265
Normal Mode
265
Peak Detect Mode
266
High Resolution Mode
266
Averaging Mode
267
Realtime Sampling Option
269
Segmented Memory
271
Using Segmented Memory
271
Web Interface
275
Setting up the Oscilloscope's LAN Connection
276
To Establish a LAN Connection
276
To Establish a LAN Connection (6000L Series)
277
Stand-Alone (Point-To-Point) Connection to a PC
278
Accessing the Web Interface
280
Browser Web Control
281
Remote Front Panel
281
Remote Programming
283
Remote Programming with Agilent IO Libraries
284
Get Image
285
Identification Function
286
Instrument Utilities
287
Setting a Password
288
Serial Decode/Lister
291
Serial Decode
292
Lister
293
Serial Decode Lister
293
CAN Serial Decode
295
Interpreting CAN Decode
298
CAN Totalizer
299
Interpreting CAN Lister Data
301
Flexray Serial Decode
302
Interpreting Flexray Frame Decode
303
Flexray Totalizer
304
Interpreting Flexray Lister Data
305
I 2 C Serial Decode
306
Interpreting I 2 C Decode
308
Interpreting I 2 C Lister Data
309
I 2 S Serial Decode
310
Interpreting I 2 S Decode
312
Interpreting I 2 S Lister Data
313
LIN Serial Decode
314
Interpreting LIN Decode
317
Interpreting LIN Lister Data
319
MIL-STD 1553 Serial Decode
320
Interpreting MIL-STD 1553 Decode
321
Viewing MIL-STD 1553 Data in the Lister
322
SPI Serial Decode
323
Interpreting SPI Decode
327
Interpreting SPI Lister Data
328
UART/RS232 Serial Decode
329
Interpreting UART/RS232 Decode
333
UART/RS232 Totalizer
334
Interpreting UART/RS232 Lister Data
335
Mask Test
337
To Create a Mask from a "Golden" Waveform (Automask)
338
Troubleshooting Mask Setup
339
Setup Options
340
Run until
340
On Error
340
Source Lock
341
Mask Test Trigger Output
342
Mask Statistics
343
Reset Statistics
344
Transparent
344
To Manually Modify a Mask File
345
Building a Mask File
348
Controls and Connectors
351
Front Panel
352
5000/6000 Series Front Panel (4-Channel)
352
5000/6000 Series Front Panel (2-Channel, Differences Only)
353
6000L Series Front and Rear Panel
354
7000 Series Front Panel (4-Channel)
355
7000 Series Front Panel (2-Channel, Differences Only)
356
Front Panel Control and Connector Descriptions
357
Do Not Connect a Host Computer to the Oscilloscope's USB Host Port
357
Rear Panel
362
5000 Series Rear Panel (4-Channel)
362
5000 Series Rear Panel (2-Channel)
363
6000 Series Rear Panel (4-Channel)
364
6000 Series Rear Panel (2-Channel)
365
6000 Series Option BAT Rear Panel (4-Channel)
366
7000 Series Rear Panel (4-Channel)
367
7000 Series Rear Panel (2-Channel)
368
Rear Panel Control and Connector Descriptions
369
Digital Channels
371
To Connect the Digital Probes to the Device under Test
372
Probe Cable for Digital Channels
372
Acquiring Waveforms Using the Digital Channels
375
To Display Digital Channels Using Autoscale
376
Example
376
Interpreting the Digital Waveform Display
378
To Change the Displayed Size of the Digital Channels
379
To Switch a Single Channel on or off
379
To Switch All Digital Channels on or off
379
To Switch Groups of Channels on or off
379
To Change the Logic Threshold for Digital Channels
380
To Reposition a Digital Channel
380
To Display Digital Channels as a Bus
381
Digital Channel Signal Fidelity: Probe Impedance and Grounding
385
Input Impedance
385
Probe Grounding
387
Best Probing Practices
388
To Replace Digital Probe Leads
389
Utilities
391
To Restore the Oscilloscope to Its Default Configuration
392
To Perform Service Functions
393
User Calibration
394
Self Test
397
Reference
399
About Oscilloscope
400
Software and Firmware Updates
400
Installed Licenses
400
Upgrading to an MSO
401
Secure Environment Mode Option
402
Measurement Category
403
Measurement Category Definitions
403
Transient Withstand Capability
404
Maximum Input Voltage at Analog Inputs and 2-Channel External Trigger Input
404
Maximum Input Voltage at Digital Channels
404
Environmental Conditions
405
Using the 10 Mhz Reference Clock
406
Sample Clock and Frequency Counter Accuracy
406
Supplying an External Timebase Reference
406
To Supply a Sample Clock to the Oscilloscope
406
Maximum Input Voltage at 10 Mhz REF Connector
406
To Synchronize the Timebase of Two or more Instruments
408
To Clean the Oscilloscope
408
Binary Data (.Bin) Format
409
Binary Data in MATLAB
409
Binary Header Format
410
Example Program for Reading Binary Data
413
Examples of Binary Files
414
CSV and ASCII XY Files
417
Acknowledgements
418
To Check Warranty and Extended Services Status
418
To Return the Instrument
419
Contact Us
420
Advertisement
Related Products
Agilent Technologies InfiniiVision DSO7104B
Agilent Technologies InfiniiVision DSO7012B
Agilent Technologies InfiniiVision DSO7032B
Agilent Technologies InfiniiVision DSO7034B
Agilent Technologies InfiniiVision DSO7052B
Agilent Technologies InfiniiVision DSO7054B
Agilent Technologies InfiniiVision DSO7032A
Agilent Technologies InfiniiVision DSO7052A
Agilent Technologies InfiniiVision DSO7014A
Agilent Technologies InfiniiVision DSO7034A
Agilent Technologies Categories
Measuring Instruments
Laboratory Equipment
Test Equipment
Water Pump
Power Supply
More Agilent Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL