Table 76 Snmp System Traps - ZyXEL Communications ONU-2024 Series User Manual

Table of Contents

Advertisement

Chapter 27 Access Control
An OID (Object ID) that begins with "1.3.6.1.4.1.890.1.5.8.16" is defined in private MIBs.
Otherwise, it is a standard MIB OID.

Table 76 SNMP System Traps

OPTION
OBJECT LABEL
coldstart
coldStart
warmstart
warmStart
fanspeed
FanSpeedEventOn
FanSpeedEventClear
temperature TemperatureEventOn
TemperatureEventClear
voltage
VoltageEventOn
VoltageEventClear
reset
UncontrolledResetEventOn
ControlledResetEventOn
RebootEvent
timesync
RTCNotUpdatedEventOn
RTCNotUpdatedEventClear
intrusionloc
IntrusionLockEventOn
k
loopguard
LoopguardEventOn
202
OBJECT ID
1.3.6.1.6.3.1.1.5.1
1.3.6.1.6.3.1.1.5.2
1.3.6.1.4.1.890.1.5.8.16.27.2.1 This trap is sent when the fan speed
1.3.6.1.4.1.890.1.5.8.27.27.2.2 This trap is sent when the fan speed
1.3.6.1.4.1.890.1.5.8.16.27.2.1 This trap is sent when the
1.3.6.1.4.1.890.1.5.8.27.27.2.2 This trap is sent when the
1.3.6.1.4.1.890.1.5.8.27.27.2.1 This trap is sent when the voltage
1.3.6.1.4.1.890.1.5.8.27.27.2.2 This trap is sent when the voltage
1.3.6.1.4.1.890.1.5.8.16.27.2.1
1.3.6.1.4.1.890.1.5.8.27.27.2.1
1.3.6.1.4.1.890.1.5.8.16.27.2.1
1.3.6.1.4.1.890.1.5.8.27.27.2.1
1.3.6.1.4.1.890.1.5.1.1.2
1.3.6.1.4.1.890.1.5.8.16.27.2.1
1.3.6.1.4.1.890.1.5.8.27.27.2.1
1.3.6.1.4.1.890.1.5.8.16.27.2.2
1.3.6.1.4.1.890.1.5.8.27.27.2.2
1.3.6.1.4.1.890.1.5.8.16.27.2.1
1.3.6.1.4.1.890.1.5.8.27.27.2.1
1.3.6.1.4.1.890.1.5.8.16.27.2.1
1.3.6.1.4.1.890.1.5.8.27.27.2.1
DESCRIPTION
This trap is sent when the ONU is
turned on.
This trap is sent when the ONU
restarts.
goes above or below the normal
operating range.
returns to the normal operating
range.
temperature goes above or below
the normal operating range.
temperature returns to the normal
operating range.
goes above or below the normal
operating range.
returns to the normal operating
range.
This trap is sent when the ONU
automatically resets.
This trap is sent when the ONU
resets by an administrator through a
management interface.
This trap is sent when the ONU
reboots by an administrator through
a management interface.
This trap is sent when the ONU fails
to get the time and date from a time
server.
This trap is sent when the ONU gets
the time and date from a time server.
This trap is sent when intrusion lock
occurs on a port.
This trap is sent when loopguard
shuts down a port.
ONU User's Guide

Advertisement

Table of Contents
loading