4. Installation
A. Lock release
(1) Scanner (2/3 mirror unit) lock release
1)
Remove the optical unit fixing screw and remove the note
label.
(2) Tray rotation plate lock release
1)
Pull out the tray, and remove the rotation plate fixing material
and the tray note label.
(Tray 1, tray 2)
(Tray 3, tray 4)
2)
Attach the removed fixing material to the position shown in the
figure for storage.
B. Fusing heat roller pressing
1)
2)
NOTE: If the machine is left unused for one month or more, the
MX-7000N MX-5500N/6200N/7000N 1 – 5
Release the lock, and open the right door.
Lower the pressure release lever to apply more pressure.
heat roller rubber may be deformed. In such a case,
release the pressure by pushing up both levers.