D. Installation of the short-circuit harness
* As for the following procedures, only destinations other than
North America, Australia, and New Zealand are required. For
North America and Australia, New Zealand, progress to the pro-
cedure of "E. Installation of the reverse detection lever".
1)
Remove the screw, and remove the switch cover.
2)
Install the short harness (Package part No. 7).
3)
Install the switch cover, and fix it with the screw.
E. Installation of the reverse detection lever
1)
Install the reverse detection lever (Package part No. 6).
* Be careful of the installing direction of the reverse detection
lever.
F. Installation of the right rail
1)
Fix the right rail mounting fixture (Package part No. 5) to the
main unit with the fixing screws (Package part No. 1).
2)
Engage the right rail (Package part No.10) to cut-out portion of
main frame. (Refer to (A) and (B).)
Install the right rail while pressing so that engage the projec-
tion of the main unit frame with the hole (C) in rear side of the
right rail.
* When installing, check that the reverse detection lever (D) is
in the cut-out portion in the sheet metal of the right rail.
C
A
MX-7000N MX-RBX2 4 – 3