Gree GUHD09NK3FO Service Manual page 89

U-match iv series dc inverter air conditioners
Hide thumbs Also See for GUHD09NK3FO:
Table of Contents

Advertisement

U-Match Series DC
Inverter Service Manual
F1 Malfunction of Evaporator Temperature Sensor
F2 Malfunction of Condenser Temperature Sensor
86
Malfunction of
evaporator
temperature
sensor
Check if the evaporator
temperature sensor on
mainboard is inserted on the
needle stand correctly
Yes
Disconnect
the temperature sensor and
measure if its resistance is
normal
Yes
Replace the
indoor
mainboard
Malfunction of
condenser
temperature
sensor
Check if the condenser
temperature sensor on
mainboard is inserted on the
needle stand correctly
Yes
Disconnect
the temperature sensor and
measure if its resistance is
normal
Yes
Replace the
outdoor
mainboard
Correctly insert the
temperature
No
sensor on the
needle stand
Replace the
No
temperature
sensor
Correctly insert the
No
temperature sensor
on the needle stand
No
Replace the
temperature sensor

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents