Page 1
GTH42K3CI GUHD42NK3CO GUHD42NK3C1O GTH48K3CI GUHD48NK3CO GUHD48NK3C1O GTH36K3CI GUHD36NM3CO GUHD36NM3C1O GTH42K3CI GUHD42NM3CO GUHD42NM3C1O GTH48K3CI GUHD48NM3CO GUHD48NM3C1O GTH60K3CI GUHD60NM3CO GUHD60NM3C1O GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Please read this manual carefully before using this product and keep it properly for future reference.
Page 2
User Notice ● Ensure unified power supply for each indoor unit. ● Never install wired controller in wet place or under sunlight directly. ● Shielding twisted pair line must be adopted as signal line or wiring (communication) of wired controller once the unit is installed in the place where there is electromagnetic interference. ●...
DC Inverter Floor Ceiling Type Air Conditioner Safety Considerations Please read this manual carefully before use and operate correctly as instructed in the manual. You are specially warned to note the two symbols below: A symbol indicating that improper operation might cause human death or severe injury; A symbol indicating that improper operation might cause human property damage.
Page 6
DC Inverter Floor Ceiling Type Air Conditioner ● An all-pole disconnection switch with a contact separation of at least 3mm in all poles should be connected with the fixed wiring. ● The appliance should be installed in accordance with national wiring regulations. ●...
DC Inverter Floor Ceiling Type Air Conditioner 1. Displaying Part Fig.1 Outline of wired controller 1.1 LCD Display of Wired Controller Fig.2 LCD display...
DC Inverter Floor Ceiling Type Air Conditioner 1.2 Instruction to LCD Display Table 1 Instruction to LCD Display Description Instruction to Displaying Contents Swing Swing function Air * Air exchange function Sleep Sleeping states Each kind of running mode of in Each kind of running mode of indoor Running mode unit (auto mode) Cooling...
DC Inverter Floor Ceiling Type Air Conditioner 2. Buttons 2.1 Silk Screen of Buttons 2.2 Instruction to Function of Buttons Table 2 Instruction to Function of Buttons Description Function of Button ① Function selection and canceling; Enter/Cancel ② Press it for 5s to enquiry the outdoor ambient temperature. ▲...
DC Inverter Floor Ceiling Type Air Conditioner 3. Installation of Wired Controller Fig.4 Sketch for Installation of Wired Controller Socket’s base box Soleplate of Screw Front panel of Description installed in the controller M4X25 controller Screw ST2.2X6.5 wall Fig.4: Sketch for Installation of Wired Controller. Pay attention to the following items during installation of wired controller: 1.
DC Inverter Floor Ceiling Type Air Conditioner 4. Instruction to Operation 4.1 On/Off Press On/Off button to turn on the unit. Repress this button to turn off the unit. Note: The state shown in Fig.5 indicates off-state of the unit after energization. The state shown in Fig.6 indicates on-state of the unit after energization.
DC Inverter Floor Ceiling Type Air Conditioner 4.3 Temperature Setting Press ▲ or ▼button to increase or decrease of setting temperature under on-state of the unit. If press either of them continuously, temperature will be increased or decreased by 1°C every 0.5s. In Cooling, Dry, Fan and Heating mode, temperature setting range is 16°C~30°C.
DC Inverter Floor Ceiling Type Air Conditioner 4.5 Swing Control Function Under on-state of unit, press Function button till the unit enters swing control function and then press Enter/Cancel button to turn on “swing” control function. During swing function, press Function button till the unit enters swing control function and then press Enter/Cancel button to cancel swing control function.
DC Inverter Floor Ceiling Type Air Conditioner (continued) Fig.9 Swing control function setting 4.6 Timer Setting Press Timer button to set timer off of the unit. Under off-state of the unit, press Timer button to set timer on of the unit in the same way. Timer on setting: Under off-state of the unit without timer setting, if Timer button is pressed, LCD will display xx.
Page 15
DC Inverter Floor Ceiling Type Air Conditioner Fig.10 Timer setting under on state of the unit...
DC Inverter Floor Ceiling Type Air Conditioner Timer range: 0.5-24hr. Every press of▲ or ▼ button will make setting time increased or decreased by 0.5hr.If press either of them continuously, setting time will automatically increase/ decrease by 0.5hr every 0.5s. Note: 1.
DC Inverter Floor Ceiling Type Air Conditioner (continued) Fig.11 Air exchange device Note:In air exchange mode, press Function button or there is not any operation within 5s after the last button operation, the system will be quit from air exchange setting and current energy-saving data won’t be memorized.
Page 18
DC Inverter Floor Ceiling Type Air Conditioner Sleep setting is shown as Fig.12: Fig.12 Sleep setting...
DC Inverter Floor Ceiling Type Air Conditioner Sleep setting is clear after power failure and then power recovery. There is not sleep function in fan and auto mode. Note: In cooling and dry mode, if the unit with sleep function has run for 1 hour, the preset temperature will be increased by 1°C and 1°C in another 1 hour.
DC Inverter Floor Ceiling Type Air Conditioner (continued) Fig.13 Turbo Function Setting Note: 1. TURBO function will be turned off after power failure and then recovery. In dry, fan and auto mode, TURBO function can not be set and TURBO mark won’t be displayed. 2.
Page 21
DC Inverter Floor Ceiling Type Air Conditioner Fig.14 Energy Saving Setting...
DC Inverter Floor Ceiling Type Air Conditioner Note: 1. In Auto running mode with save function on, the unit will be forcibly quit Auto running Mode and change to current operation mode, After setting of save, sleep function will be canceled. 2.
DC Inverter Floor Ceiling Type Air Conditioner (continued) Fig.15 Auxiliary Electric Heating Function Setting Note: E-HEATER can not be set in cooling, dry and fan mode, E-HEATER mark won’t be displayed. The setting is shown in Fig.15. 4.12 Blow Function Setting BLOW function: After the unit is turned off, water in evaporator of indoor unit will be automatically evaporated to avoid mildew.
Page 24
DC Inverter Floor Ceiling Type Air Conditioner Fig.16 Blow function setting...
DC Inverter Floor Ceiling Type Air Conditioner Note: 1. After setting BLOW function, turn off the unit by pressing On/Off button on remote controller, indoor fan will run at low fan speed for 10 min. (BLOW shows).Meanwhile, if BLOW function is canceled indoor fan will be turned off directly.
DC Inverter Floor Ceiling Type Air Conditioner (continued) Fig.17 Quiet function setting Note: 1. During quiet function, fan speed is un-adjustable. 2. When turning on auto quiet function, the unit will enter quiet running state according to temperature difference between room temperature and setting temperature. In this case, fan speed is adjustable. If temperature difference between room temperature and setting temperature ≥...
DC Inverter Floor Ceiling Type Air Conditioner 5.14.2 Three Grades of Speed for Indoor Fan In field setting mode, press Mode button to adjust the temperature displayed location displaying 01 and press ▲ or ▼ button to adjust setting state at timer displayed location. There are 2 types for selection: ●...
Page 28
DC Inverter Floor Ceiling Type Air Conditioner in 20 seconds on this interface after the last button press, the system will quit automatically to the normal off status without saving the current setting. Note: If there is only one wired controller, it only can be set as the master; otherwise the unit won’t run normally.
DC Inverter Floor Ceiling Type Air Conditioner 5. Error Display If there is malfunction during running of the system, LCD will display error code at temperature– displayed location. Once there is more than one malfunction, error codes will be displayed circularly. If there are multiple circuit systems, the system number of failed system will be displayed before the colon (not for single system).
Page 30
DC Inverter Floor Ceiling Type Air Conditioner The LED Indicator Display on the Main Board of Outdoor Unit (12K) This table is applicable to the electric control box of the 12K C Series DC inverter air conditioners. Some of the items are not malfunction; they mean the normal running status. wired Outdoor unit Outdoor unit...
Page 31
DC Inverter Floor Ceiling Type Air Conditioner Definition of Malfunction Codes of DC Inverter General Outdoor Unit (V1.6) This table is applicable to the electric control box of the other models of C-Series DC inverter air conditioners. Outdoor unit display of dual 8 Malfunction Item Indoor Unit Display numeral tube...
DC Inverter Floor Ceiling Type Air Conditioner 6. Remote Control Operation Procedure(standard fitting) 6.1 Name and Function-Remote Control Note: Be sure that there are no obstructions between receiver and remote controller. Don’ t drop or throw the remote controller . Don’...
DC Inverter Floor Ceiling Type Air Conditioner 6.2 Name and Function-Remote Control. (Remove the cover) Note: This type of remote controller is a kind of new current controller. Some buttons of the controller which are not available to this air conditioner will not be described below. Operate on unmentioned buttons would not impact on the normal use.
DC Inverter Floor Ceiling Type Air Conditioner 6.3 COOL mode operation procedure According to difference between room temp. and set temp., microcomputer can control cooling on or not. If room temp. is higher than set temp., compressor runs at COOL mode. If room temp.
DC Inverter Floor Ceiling Type Air Conditioner 6.4 HEAT mode operation procedure If room temp. is lower than set temp. compressor runs at HE AT mode; If room temp. is higher than set temp., compressor and outdoor fan motor stop, only indoor fan motor runs.
DC Inverter Floor Ceiling Type Air Conditioner 6.5 DRY mode operation procedure If room Temp. is more than 2°C below Set TEMP. , compressor and outdoor unit fan motor stop, indoor unit fan motor runs at low speed. If room Temp. is between 2°C of Set TEMP. , the compressor and outdoor unit fan motor will run for 6 minutes and stop for 4 minutes, and always in such a cycle, the indoor unit fan motor will run at low speed.
DC Inverter Floor Ceiling Type Air Conditioner 6.6 AUTO mode operation procedure According to room temp. microcomputer can automatically set COOL.HEAT.DRY operation mode, so as far best effect. At AUTO mode operation, standard TEMP. is 26°C for COOL mode, 24°C for DRY mode and 20°C for HEAT mode.
DC Inverter Floor Ceiling Type Air Conditioner 6.7 FAN mode operation procedure Connect the unit to power supply. Press the “ON/OFF” key. Press the mode key to select the “FAN” mode. The unit shall operate under “FAN” mode. Press the “FAN” key to select from high, medium and low speed.
DC Inverter Floor Ceiling Type Air Conditioner 6.9 SLEEP mode operation procedure When the unit is cooling or drying, if SLEEP operation is set, TEMP. would increase 1°C in 1 hour and 2°C in 2 hours. Indoor fan motor runs at low speed. When the unit is heating , if SLEEP operation is set, TEMP.
DC Inverter Floor Ceiling Type Air Conditioner 7. Part Names and Their Functions Fig.30 CAUTION: ● Wrong wiring connection will cause electrical malfunction. ● Do not pull the wire when fixing it with wire. Notes: ● If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
DC Inverter Floor Ceiling Type Air Conditioner Maintenance Before inspection and maintenance of the unit, please shut down the unit and set the power switch to “OFF” to cut off the power supply. C leaning the Air Filter ① . Remove the air filter;...
DC Inverter Floor Ceiling Type Air Conditioner Operating Guide The cleaning and replacement of the filter is only permitted to be done by the professionals. Before open the grille to clean the filter, please cut off the power supply and wait unit the fan motor stops. T he temperature should not be set lower than what you need, otherwise it would result in increased ①...
DC Inverter Floor Ceiling Type Air Conditioner Precautions T urn off the air conditioner if it is not needed, as electricity interference may occurs while it is ① . running .If the unit is not to be used for a long time, cut off the power supply main switch. Fig.36 D o not insert objects into the air inlet or outlet when the air conditioner is running as it may cause ②...
DC Inverter Floor Ceiling Type Air Conditioner 11. Checking Before Contact the Service Man Check the followings before contact the service man. You may find the solution to your problems. After checking, if it still does not operate, please contact your local dealer. Table.3 Problem Solution(s)
Page 47
DC Inverter Floor Ceiling Type Air Conditioner Table.5 Accessories List for Installation (Indoor Unit) Number Name Shape Quantity Type Remark Nut (with gasket) Tie Line 200mm used for Installation ceiling Paperboard drilling Thermal Insulation Layer of Discharge Pipe Thermal Insulation Layer of Inlet Liquid Pipe Sealing Plaster*...
When install the indoor unit, you can use a paper pattern for reference and make sure that the drainage side be 10mm lower than the other side in order to drain the condensation water fluently. Fig.39 Table.6 Unit: mm Model GTH09K3CI GTH12K3CI 1220 1158 GTH18K3CI GTH24K3CI...
Page 49
DC Inverter Floor Ceiling Type Air Conditioner Selection of Installation Location S uch a place where cool air can be distributed throughout the room. ① . S uch a place where condensation water is easily drained out. ② . S uch a place that can handle the weight of indoor unit. ③...
Page 50
DC Inverter Floor Ceiling Type Air Conditioner Set the suspension bolt. (Use M10 size suspension bolts) Adjust the distance between the unit and the ceiling slab beforehand (See Fig.43). Fix the hanger bracket to the suspension bolt. WARNING! ● Make sure that extended suspension bolt from the ceiling stays inside the arrowed position. Readjust the hanger bracket when it is outside the arrowed position.
DC Inverter Floor Ceiling Type Air Conditioner 11.3 Installation of the Outdoor Unit 11.3.1 Installation Location of the Outdoor Unit The foundation must be solid enough to bear the weight and vibration of the unit. The space around the unit is adequate for ventilation. The location is not close to any inflammable gases.
Page 52
DC Inverter Floor Ceiling Type Air Conditioner T he rated voltage and the exclusive circuit must be used. ⑥ . L eakage circuit-breaker must be installed. ⑦ . P lease use the specified fuse. ⑧ . I f the power supply cord of the unit is damaged it must be replaced by ⑨...
The section area of cables selected by users must not be smaller than the specifications shown in the following diagram. The signal wire between indoor and outdoor unit will be installed in the shielded bushing Fig.54-1 GUHD09NK3CO + GTH09K3CI GUHD09NK3C1O + GTH09K3CI GUHD12NK3CO + GTH12K3CI GUHD12NK3C1O + GTH12K3CI 1.Power cord 3×2.5 mm...
DC Inverter Floor Ceiling Type Air Conditioner 11.5 Connecting Pipe Preparation 11.5.1 Pipe Preparation 1. Pipe & Electrical Wire Cutting ● Use cutting tools easily found in the market. ● Measure precisely both outer & inter pipes. ● The length of the pipe should be a little longer than the actual measured value.
Page 59
DC Inverter Floor Ceiling Type Air Conditioner Avoid pipe bending as much as possible, if it is necessary, the bending radius must be more than 3 or 4 Connection between an Indoor unit and an Outdoor Unit: U nscrew the flare nut for releasing pressure gas in the indoor unit. If there is no high pressure gas ①...
Page 60
DC Inverter Floor Ceiling Type Air Conditioner 11.5.4 Liquid Pipe and Drain Pipe If the outdoor unit is installed lower than the indoor unit (See Fig.63). ● A drain pipe should be above ground and the end of the pipe does not dip into water.
Page 61
DC Inverter Floor Ceiling Type Air Conditioner Confirm that smooth drainage is achieved after the pipe working. Inject 600cc water into the drain pan from the air outlet to see if the drainage goes well or not. (See Fig.69) 11.5.6 Routine Checks after Installation Check after installation Table.11 Items to be checked...
Page 62
DC Inverter Floor Ceiling Type Air Conditioner WARNING! : This appliance is not intended for use by persons (including children) with reduced physical sensory or capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use the appliance by a person responsible for their safety.
DC Inverter Floor Ceiling Type Air Conditioner 12. Appendix Air conditioner nominal working condition and working range: Indoor side Outdoor side Test condition DB( ℃ ) WB( ℃ ) DB( ℃ ) WB( ℃ ) Nominal cooling Nominal heating Rated cooling Low temp cooling 18(-15) Rated heating...
Page 64
Gree Electric Appliances , Inc. of Zhuhai Jin Ji West Road, Qianshan, Zhuhai, Guangdong 519070 P.R. China http: //www. gree. com GREE 66179415...