External Control Protocol

External Control Protocol
The DDS 5900 Digital Discussion System features an Ethernet connection for the purpose of providing an interface to
control and monitor the system. By setting up a simple (raw) TCP/IP socket connection to the CU 5905 Central Unit,
control options are available.
This section describes the TCP/IP raw socket protocol for communicating with the DDS 5900 Discussion System. This
protocol provides a short set of commands, enabling a third part control application to monitor and/or control system
status of a DDS 5900 Discussion System.
Some examples of functionality available using the protocol:
• Setting a microphone in speak or in request
• Retrieving a list of seats available in the system.
This interface supports applications developed by customers, so the protocol is deliberately kept simple. The External
Control protocol offers a means for supplementing the control functionality available through the DDS 5900 Browser
interface and the CU 5905 interactive display, however some commands and settings available in the browser interface
and on the CU 5905 interactive display are not available using the 'External Control Protocol'
Customer applications can include but are not limited to AMX
or Crestron
room control systems, PC or micro controller
®
®
based applications, e.g., for button mimics and camera control applications.

General Protocol Behavior

TCP/IP socket connection
A TCP/IP socket connection to the CU 5905 must be established for the External Control protocol to become available.
Configuration of the CU 5905 connection to the Ethernet must be defined from the CU interactive front plate control/
Browser interface and an IP address for the CU 5905 must be assigned in the network.
Choose either a static IP address or an IP address assigned through DHCP. It is convenient to ensure, that the CU 5905
ends up with the same IP address at each start up.
Knowing the IP address, the only additional information required for setting up a TCP/IP connection is the Port Number:
Port Number = 3142
Example: Test connection to CU via Putty
: If the CU 5905 is assigned IP address 192.168.1.100, the external
®
application must connect the TCP/IP socket to the address 192.168.1.100:3142.
Knowing the IP address of the CU 5905 a connection can be set up using a simple terminal program like Putty.
1. Download at www.putty.org
2. Start Putty.
3. Insert IP address and Port Number.
4. Select 'Raw' for the Connection Type.
5. Press 'Open' to establish connection to the CU. Control is now possible.
6. Type 'help' to see a list of commands available.
Command Structure (from External Control to CU 5905)
To control the CU an External Control sends commands to CU 5905 included in command lines. Commands lines are
build up in a very simple manner:
<command><SP><data><CR>
<command><SP><data><LF>
<SP>
Space - 0x20 = 32
52