Camus Hydronics DFH/W500 Installation, Operation And Service Manual page 12

Dynaflame series gas fired commercial copper tube and stainless steel boilers
Table of Contents

Advertisement

Model
Width "A" Depth "B" Height "C"
500
25
27
45 5/8
750
25
27
55
1100
25
27
68 1/4
1200
25
27
68 1/4
1500
29 3/8
31 3/4
58 1/8
1750
29 3/8
31 3/4
62 5/8
2000
29 3/8
31 3/4
66 7/8
2500
29 3/8
31 3/4
73 1/2
3000
29 3/8
31 3/4
79 1/2
3500
29 3/8
31 3/4
86 1/2
4000
29 3/8
31 3/4
91 1/2
4500
29 3/8
31 3/4
96 1/2
5000
29 3/8
31 3/4
101 1/2
4504
35 3/4
39 1/4
83
5004
35 3/4
39 1/4
88 1/4
6004
35 3/4
39 1/4
102
Copper and copper nickel heat exchanger
500 – 1200 appliance inlet/outlet connections are 2" NPT
1500 – 5000 appliance inlet/outlet connections are 3" NPT
DynaFlame® Non-Condensing
Vent Diameter Inches
Cat III
Model
Outdoor
Up to
50 ft
0500
4
4
0750
6
6
1100
6
6
1200
6
6
1500
7
7
1750
7
7
2000
8
8
2500
8
8
3000
8
8
3500
9
9
4000
9
9
*4500
10
10
4504
10
10
*5000
10
10
5004
10
10
6004
12
12
7
Table 3: Appliance Dimensions and Specifications [in.]
Gas
Water
Air Inlet
Flue Height
Height
Conn. "D"
"E"
"F"
"G"
27
37 1/4
13 1/4
33 5/8
36 3/8
46 5/8
15 3/4
43
49 5/8
59 7/8
22
56 1/4
49 5/8
59 7/8
22
56 1/4
38 1/4
48 5/8
16 3/8
45 7/8
42 5/8
53 1/8
16 3/8
50 3/8
46 7/8
57 3/8
20
53 5/8
52 5/8
63 5/8
25 3/4
60 3/8
58 5/8
69 5/8
31 3/4
66 3/8
63 5/8
76
24 7/8
72 5/8
68 5/8
81
29 7/8
77 5/8
73 5/8
86
34 7/8
82 5/8
78 5/8
91
39 7/8
87 5/8
59 3/4
72 1/4
20 3/4
67 7/8
65
77 1/2
26
72 1/4
75 1/2
91
35 1/2
85 1/2
Table 4: Vent Sizes for a Single Appliance
DynaFlame® Near-Condensing (DFX)
Cat III
Model
Up to
Cat I
Outdoor
100 ft
6
8
0501
8
10
0751
8
10
1101
8
10
1201
10
12
1501
10
12
1751
12
14
2001
12
14
2501
12
14
3001
14
16
3501
14
16
4001
14
16
*4501
14
16
4514
14
16
*5001
14
16
5014
14
16
6014
"H"
"I"
"J"
"K"
17 3/4
6
4 1/8
2 5/8
11 1/2
25
6
4 1/8
2 5/8
11 1/2
31 1/8
6
4 1/8
2 5/8
11 1/2
31 1/8
6
4 1/8
2 5/8
11 1/2
24 1/2
6
3 7/8
1 7/8
13 1/2
24 1/2
6
3 7/8
1 7/8
13 1/2
28 3/4
6
3 7/8
1 7/8
13 1/2
34 1/2
6
3 7/8
1 7/8
13 1/2
40 1/2
6
3 7/8
1 7/8
13 1/2
32 7/8
20
3 7/8
1 7/8
13 1/2
32 7/8
20
3 7/8
1 7/8
13 1/2
42 7/8
20
3 7/8
1 7/8
13 1/2
47 7/8
20
3 7/8
1 7/8
13 1/2
28 7/8
20
2 1/2
3 1/2
17 7/8
34 1/8
20
2 1/2
3 1/2
17 7/8
44 5/8
20
2 1/2
2 3/4
17 7/8
Stainless steel heat exchanger:
500 – 1200 appliance inlet/outlet connections are 2" groove lock
1500 – 2500 appliance inlet/outlet connections are 2-1/2" groove lock
3000 - 5000 appliance inlet/outlet connections are 3" groove lock
4504 - 6004 appliance inlet/outlet connections are 4" groove lock
Vent Diameter Inches
Cat IV
Cat IV
Up to
Up to
Cat II
50 ft
100 ft
4
4
6
5
6
6
8
6
6
6
8
7
6
6
8
7
7
7
10
8
7
7
10
8
8
8
12
9
8
8
12
9
8
8
12
10
9
9
14
12
9
9
14
12
10
10
14
12
10
10
14
12
10
10
14
12
10
10
14
12
12
12
14
12
Water
Air Inlet
"L"
"M"
"N"
Conn.
Dia. "W"
Prim.
18 3/4
6 1/4
6
2
18 3/4
6 1/4
8
2
18 3/4
6 1/4
8
2
18 3/4
6 1/4
8
2
22 3/8
10 1/4
10
2 1/2
22 3/8
10 1/4
10
2 1/2
22 3/8
10 1/4
12
3
22 3/8
10 1/4
12
3
22 3/8
10 1/4
12
3
22 3/8
10 1/4
14
4
22 3/8
10 1/4
14
4
22 3/8
10 1/4
14
4
22 3/8
10 1/4
14
4
25 5/8
12
14
4
25 5/8
12
14
4
25 5/8
12
14
4
DynaFlame® Condensing
Vent Diameter Inches
Cat IV
Model
Outdoor
Up to
50 ft
0502
4
4
0752
6
6
1102
6
6
1202
6
6
1502
7
7
1752
7
7
2002
8
8
2502
8
8
3002
8
8
3502
9
9
4002
9
9
*4502
10
10
4524
10
10
*5002
10
10
5024
10
10
6024
12
12
Water Conn.
Gas Conn.
Sec. Grooved
[NPT]
(Optional)
1 1/2
1
1 1/2
1
1 1/2
1
1 1/2
1
1 1/2
1 1/4
1 1/2
1 1/4
1 1/2
1 1/4
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2
2
1 1/2
2
1 1/2
2 1/2
1 1/2
2 1/2
1 1/2
2 1/2
1 1/2
2 1/2
1 1/2
3
Cat IV
Up to
Cat II
100 ft
6
5
8
6
8
7
8
7
10
8
10
8
12
9
12
9
12
10
14
12
14
12
14
12
14
12
14
12
14
12
14
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents