Electric Motor

Installation

1 Phase, 240 VAC, 50 Hz Electric Motor
133
205
43
99
ti18343a
204
193
191
192
1. Install pulley (43) and set screws (133). Torque set
screws to 60 in-lb (6.8 N•m). Make sure pulley is
flush with end of electric motor shaft.
2. Install handle (175), bottom isolator plate (190) and
rocker plate (99) to electric motor (119) with four
screws (30) and nuts (174). Motor should be posi-
tioned all the way forward on rocker plate. Torque
screws (30) to 225 in-lb (25.4 N•m).
20
3. Install motor assembly on sprayer.
119
30
4. Swing electric motor retainer bracket (204) in.
Tighten electric motor nut (205).
175
190
5. Install Fan Belt, page 14.
6. Check to make sure fan pulley and motor pulley are
174
in line. Also check to make sure fan pulley shaft and
motor pulley shaft are parallel. Adjust as required.
Parallel
ti18697a
ti18750a
ti18193a
ti5387a
(end of motor pulley should
be flush with end of motor shaft)
In Line
Motor Pulley (133)
Motor Shaft
Fan Pulley Shaft
Fan Pulley (43)
3A2247A