Fan Belt; Removal; Installation - Graco DutyMax 24M054 Repair Manual

Hydraulic sprayers
Hide thumbs Also See for DutyMax 24M054:
Table of Contents

Advertisement

Fan Belt

Fan Belt

Removal

This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing fluid
and moving parts, follow the Pressure Relief Proce-
dure when you stop spraying and before cleaning,
checking, or servicing the equipment.
1. Perform Pressure Relieve Procedure, page 9.
2. Loosen belt guard knob (55).
3. Rotate belt guard (117) up.
117
96
14
4. Lift electric motor or gas engine up to remove ten-
5. Remove belt from pulley (43) and fan pulley (96).

Installation

1. Thread belt (44) around drive pulley (43) and fan
2. Let electric motor (119) down to put tension on belt.
3. Rotate belt guard (117) down.
4. Tighten belt guard knob (55).
44
119
43
55
sion on belt (44).
pulley (96).
Unit
24M054
24M055
24M056
24M057
ti18342a
Belt Table
Part Number
Description
116914
V-Belt AX42
119433
V-Belt AX41
125834
V-belt AX48
119432
V-Belt Ax44
3A2247A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dutymax 24m055Dutymax 24m056Dutymax 24m057

Table of Contents