Fluorescent Option Kit - ETC DRd6-12-120 Installation Manual

Drd rack enclosure
Table of Contents

Advertisement

F l u o r e s c e n t O p t i o n K i t
I n s t a l l t h e F l u o r e s c e n t O p t i o n K i t
The fluorescent option (DRd-FLO) kit provides 24 outputs for control of 4-wire (0-10 Vdc)
fluorescent ballasts. Each channel output is linked one - to - one with a rack circuit for power
control. The FLO board is comprised of 24 individual 0 - 10 Vdc connections, each rated to
control a maximum of 75 fluorescent ballasts (a maximum of 400mA per channel).
Each output connection is clearly labeled on the removable screw terminal bus connectors.
The removable connectors accept 12 - 24 AWG (4 - .25mm
Step 1:
Step 2:
Step 3:
Step 4:
44
Align the FLO option board to the mounting studs in the bottom of the DRd rack.
• Notice the mounting holes on the FLO option board. One is a slotted
keyhole, another is an open ended slot, and the remaining two on the other
end of the board are standard mounting holes used to secure the board in
place.
Set the rear left stud through the slotted keyhole and align the open ended slot
with the back right side mounting stud.
Gently slide the FLO board toward the right I/O board aligning the five prong
connector to the receptacle on the I/O board.
Secure the remaining two mounting holes to the pems with the screws provided.
2
) Class 1 wire.
Step 2
Step 3
Step 4
®
Unison
DRd Rack Enclosure Installation Manual

Advertisement

Table of Contents
loading

Table of Contents