  • Page 1 Sensor Enclosure (SR+/HSR+ Series) to CEM3 Retrofit Manual Part Number: 7141M2300 Rev: C Released: 2021-03...
  • Page 2 To view a list of ET C tr ad e m a r k s a n d p a t e n t s , g o t o etcconnect.com/ip. A l l o t h e r t r a d e m a r k s , b o t h m a r k e d a n d no t m a r k e d , a r e t h e p r o p ert y o f t h ei r r es p e c ti v e o w ne r s .
  • Page 3: Overview Of This Manual

    Introduction This manual is intended to guide ETC Service Technicians through the process of upgrading existing Sensor+ enclosure installations to Sensor3 enclosures with a CEM3 control module. This manual covers SR+ or HSR+ 6, 12, 24 and 48 permanent installation enclosures.
  • Page 4: Document Conventions

    WARNING: RISK OF ELECTRIC SHOCK! This warning statement indicates situations where there is a risk of electric shock. All ETC documents are available for free download from our website: etcconnect.com. Please email comments about this manual to: TechComm@etcconnect.com. Safety Please note the following safety warnings before use: •...
  • Page 5: Help From Etc Technical Services

    Help from ETC Technical Services If you are having difficulties, and your problem is not addressed by this document, try the ETC support website at support.etcconnect.com or the main ETC website at etcconnect.com. If none of these resources are sufficient, contact ETC Technical Services directly at one of the offices identified below.
  • Page 6 The table below lists the parts and components needed to retrofit a Sensor+ rack (SR+ or HSR+ 6, 12, 24, or 48) to become a Sensor3 rack with a CEM3. Parts/Components SR+ Enclosure HSR+ Enclosure  ETC Part Number 7141K1101 7141K1004 CEM+ to CEM3 Backplane Power Adapter Harness 7141B7007 Cable tie 4"...
  • Page 7 RISK OF DEATH BY ELECTRIC SHOCK! Power down the rack before removing the CEM3. Only remove modules with the rack powered off, following these instructions or as instructed by ETC Technical Services. AVERTISSEMENT : RISQUE DE MORT PAR ÉLECTROCUTION! Mettez le rack de gradation hors tension avant de retirer le CEM3.
  • Page 8 Unscrew the backplane metal from the enclosure. (One screw in each side upper-corner - two screws total.) Discard these screws. Replacement screws with thread locker are provided (ETC Part# HW377) and will be used later. Remove the backplane screws Push the backplane towards the back of the enclosure to free the backplane side tabs.
  • Page 9 Attach New Power Harness Connect the old power connector to the new power harness adapter found in the kit. The connectors are keyed - the power connectors only fit one way. New Power Harness Run the green ground wire from the power harness adapter between the bus bar and the enclosure wall avoiding any interference with other wires in the enclosure.
  • Page 10 Backplane Settings Upgrade kit backplanes ship from the factory with all DIP switches in the off (down) position. You will have to set the DIP switches on the new backplane to match your rack. You will also have to verify the termination switch settings.
  • Page 11 Install the New Backplane Remove the three-pin Phoenix connector that ships attached to the rear of the backplane. It will not be used in this retrofit. Verify that the four-pin Molex caps are in place over the connectors next to where the phoenix connector was attached.
  • Page 12 Install the 3-pin beacon connector. The wires travel out of the bottom of the CEM3. Connect the Cat 5 Ethernet cable to the RJ-45 connector on the CEM3 backplane. (Not shown in the drawing below for clarity.). DMX B DMX A CEM3 Ribbon Cable Layout Beacon Pin-out...
  • Page 13 Install the new beacon PCB (ETC part # 7140B5620) with two screws (ETC part # HW222). (Three new screws of the same type are provided in case the old ones were damaged during the removal process.)
  • Page 14: Enclosure Door

    Enclosure Door Remove the old Sensor beacon acrylic in the door and discard by loosening the two retaining screws with a #2 Phillips screwdriver. Install the Sensor3 beacon acrylic in the door with the longer edge toward the center of the door. Carefully peel the old Sensor label from the front of the door and discard.
  • Page 15: Final Steps

    For future service needs, it is recommended that you send copies of the final CEM3 configuration files for each enclosure to ETC technical services (Lightmanager@etcconnect.com). Include your job number and the date the configuration was adjusted. Note: Send CEM3 configuration files saved out of the Sensor3 enclosure, not configuration exported from ETC Concert (if used).
  • Page 16 | Support support.etcconnect.com | Contact etcconnect.com/contactETC © 2021 Electronic Theatre Controls, Inc. | Trademark and patent info: etcconnect.com/ip Product information and specifications subject to change. ETC intends this document to be provided in its entirety. 7141M2300 Rev C Released 2021-03...