Dmx Input Wire Termination Using The Insulation Displacement Connector (Idc); Ax12X Cross-Bussed Rack Interconnection; Terminate The Unison Options (Urto And Ubpo) - ETC DRd6-12-120 Installation Manual

Drd rack enclosure
Table of Contents

Advertisement

DMX Input Wire Termination using the Insulation Displacement Connector (IDC)

The graphic below illustrates DMX termination layout for an insulation displacement
connector. This connector type is intended for use with Belden 1583A (or approved equal,
such as Category 5, 5E, or 6) cable type. Be aware that cable other than Category 5 may
have a different color code for its wire pairs.
Use the DMX Pass-Thru
connector
If daisy-chaining to
another rack or
DMX device...
Reference and follow the DMX Cable Preparation for IDC Termination instruction sheet that
is shipped with the insulation displacement pluggable connector kit (part number
4100A1013).
A X 1 2 X C r o s s - b u s s e d R a c k I n t e r c o n n e c t i o n
Termination is provided for connection of a second DRd rack when installed in a cross-
bussed application. This termination point is labeled "Dual Racks" on the right I/O board.
An interconnect cable is provided which connects rack 1, which is the rack with the ACP
installed, to rack 2, which is the secondary rack in the cross-bussed rack system. This cable
is labeled at both ends, one end indicating rack 1 and the other end indicating rack 2. You
must have installed this cable to the correct rack for proper operation.
This interconnection of racks allows full control of both DRd racks from only one
Architectural Control Processor (ACP). This may only be used in a cross-bussed rack
application.
Reference the
this termination.
T e r m i n a te t h e U n i s o n O p t i o n s ( U R T O a n d U B P O )
N o t e :
Termination is available on the right I/O for the either the Unison
Ride Through Option (URTO) or the Unison Battery Pack Option
(UBPO). You may use only one of these option kits per DRd rack.
Step 1:
Step 2:
36
DMX B
DMX A
Thru
Thru
Auxiliary Rack Enclosure Installation Manual
A single DRd rack supports the use of either the Unison Ride Thru Option (URTO)
board or the Unison Battery Pack Option (UBPO) board, but not both in one
enclosure.
Notice the two pin connector labeled "Ride Thru / Batt"
on the right I/O board.
Plug the option cable into the receptacle.
From source
From source
DMX B
DMX A
®
Unison
for instructions to accomplish
Ride Thru/Batt
DRd Rack Enclosure Installation Manual
J9
DUAL RACK
Half
LO