Where to Install the Rack Enclosure

Unison DRd rack enclosures are designed to be surface mounted on load bearing walls in
an electrical closet or a room with restricted public access. It is recommended that you
install the rack at least 36" (915mm) off the floor surface to ensure clear view of the
Architectural Control Processor (S-ACP or P-ACP) for programming and operation.
Alternatively, DRd racks may install to a floor standing pedestal (model DRd-Ped).
C l e a r a n c e R e q u i r e m e n t s
Unison dimmer racks require 12" (305mm) top clearance for proper airflow through the
cabinet. For sufficient door clearance, install the rack with at least 17" (432mm) of front
clearance and a 6" (152mm) clearance to the left of the door hinge from walls or other
equipment.
432 mm
(17")
N o t e :
R a c k D i m e n s i o n s a n d W e i g h t s
Rack Type
DRd6 rack
DRd12 rack
N o t e :
1
Prepare for Installation
914.4 mm
(36")
®
Additional Unison
dimming and auxiliary racks of the same size are the exception
to the 6" (152mm) hinge side clearance rule. Unison racks are designed for side
by side use without issue.
Height
Width
inches
mm
inches
21.8
553
17
31
787
17
For module weight please reference
Depth
mm
inches
mm
431
10
254
431
10
254
Modules Specification, page
Product
Shipping
Weight
Weight
lbs
kgs
lbs
37.8
17.2
42
51
23.1
55
56.
kgs
19.0
25
7