Fujitsu PRIMEQUEST 2000 Series Message Reference page 41

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
2C6F01FF
FRU Inactive
Meaning:
The component has stopped operating.
Corrective action:
No action is necessary.
Severity:
Info
2C6F02FF
FRU Activation Requested
Meaning:
Addition of the component has been requested.
Corrective action:
No action is necessary.
Severity:
Info
2C6F0705
FRU Comm Lost
Meaning:
The fuse has blown.
Corrective action:
Target board must be replaced.
Severity:
Error
2C6F0706
FRU Comm Lost By Local Failure
Meaning:
The I2C bus has failed (hang).
Corrective action:
Target board must be replaced.
Severity:
Error
2C6F07FF
FRU Communication Lost
Meaning:
An I2C error has occurred.
Corrective action:
Target board must be replaced.
For IOU#0 or IOU#1: When the situation does not improve it even if target board is replaced, replace DU#0.
For IOU#2 or IOU#3: When the situation does not improve it even if target board is replaced, replace DU#1.
Severity:
Error
2CEF00FF
FRU Installed
Meaning:
The component has been mounted.
Corrective action:
No action is necessary.
Severity:
Info
CA92344-0540-06
26

Advertisement

Table of Contents
loading

Table of Contents