Fujitsu PRIMEQUEST 2000 Series Message Reference page 156

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
Error: The checksum of the firmware file is invalid.
Meaning:
Checksum error has occurred in the firmware.
Corrective action:
Check the specified file.
Severity:
Error
Error: The size of the firmware file is invalid.
Meaning:
The firmware file size is invalid.
Corrective action:
Check the specified file.
Severity:
Error
Error: The CRC of the firmware file is invalid.
Meaning:
The CRC check result of the firmware file is invalid.
Corrective action:
Check the specified file.
Severity:
Error
Error: Specified file is NOT a Firmware file.
Meaning:
The specified file is not a firmware file.
Corrective action: Check the specified file.
Severity:
Error
Unable to execute the update under maintenance.
Meaning:
The firmware cannot be updated during maintenance.
Corrective action:
Wait until the maintenance work is completed, and the maintenance mode is released.
Severity:
Warning
Current firmware is newer version.
Meaning:
Cannot rewrite in the firmware of the same or older version.
Corrective action:
A force option must be added for rewriting in the firmware of the same version or old version.
Severity:
Warning
Unable to execute the online update. Please try the update after the system power off.
Meaning:
Cannot update when the partition power is On.
Corrective action:
Execute after turning Off the partition power.
Severity:
Warning
Unable to execute the update. TPM is effective.
Meaning:
The firmware cannot be updated since the TPM function is enabled.
Corrective action:
Check the TPM setting of the partition.
Severity:
Warning
CA92344-0540-06
141

Advertisement

Table of Contents
loading

Table of Contents