MMB Messages
29012
Adapter error (Write operations disabled)
800GB card
Meaning:
Write operations are disabled.
Corrective action:
It might be a temperature problem, power unit problem or life cycle problem etc...
Contact your sales representative or a field engineer.
Severity:
Warning
29013
Adapter error (Write operations disabled)
800GB card
Meaning:
Write operations are disabled.
Corrective action:
It might be a temperature problem, power unit problem or life cycle problem etc...
Contact your sales representative or a field engineer.
Severity:
Warning
29014
Adapter error (Memory is close to wearing out)
800GB card
Meaning:
The product lifetime end for write operation will come soon. If the device is still used, it will be switched to the
Read-Only mode, and then the data will NOT be written to the device anymore.
Corrective action:
Replace the PCIe-SSD card to the new one which is already purchased.
Severity:
Info
29015
Adapter error (Reliability degraded)
800GB card
Meaning:
The reliability is degraded.
Corrective action:
It might be a temperature problem, power unit problem or life cycle problem etc...
Contact your sales representative or a field engineer.
Severity:
Warning
29016
Adapter error (Temperature above warning threshold)
800GB card
Meaning:
Temperature exceeded the upper warning threshold.
Corrective action:
Reduce the load of writing operations. Check the ambient temperature and system environment as well.
Severity:
Warning
29017
Adapter error (Adapter removed)
800GB card
Meaning:
Adapter is removed.
Corrective action:
Replace the PCIe-SSD card.
Severity:
Warning