Fujitsu PRIMEQUEST 2000 Series Message Reference page 164

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

MMB Messages
Partition#x does not include the specified [GBE | PCI SLOT | DU].
Meaning:
The specified [GBE IPCI SLOT IDU] is not included in the Partition.
Corrective action:
Check the Partition configuration.
Severity:
Warning
Partition#x does not include the specified [PCI BOX | PCI SLOT].
Meaning:
The specified [PCI BOX I PCI SLOT] is not included in the Partition.
Corrective action:
Check if there is any error in the [PCI BOX I PCI SLOT] specification. Also, check the Partition configuration.
Severity:
Warning
Unable to change partition configuration because this partition is powered on.
Meaning:
The partition cannot change the partition configuration because of the state of Power On.
Corrective action:
Turn off the power of the specified partition.
Severity:
Warning
Unable to execute this command because [PCI Bus mode| TPM | Fixed mode] of the Partition#0 is
Enabled
Meaning:
DR cannot be enabled because the function that cannot coexist with DR function is enabled.
Corrective action:
Please confirm the setting of partition that DR function will be enabled.
Please set to bellow setting of partition that DR function will be enabled.
Please set the partition that makes the DR function effective as follows.
PCI Address Mode: PCI Segment Mode
TPM: Disabled
pci_express_mode: flexible
Failed to execute set partition dynamic_reconfiguration [p#] [disable|enable] command
Meaning:
Enabling/disabling of DR function of specific partition has failed.
Corrective action:
Please confirm whether there are SB and IOU in the specific partition.
Unable to change the mode while the partition is running. Please try to change the mode after the
partition is shutdown.
Meaning:
The mode cannot change while the partition is running. Please try to change the mode after the partition is
shutdown.
Corrective action:
Please try to change the mode after the partition is shutdown.
Failed to execute show partition dynamic_reconfiguration command
Meaning:
Execution of show partition dynamic_reconfiguration command has failed.
Corrective action:
Please refer to other messages. Try setting again. If it fails, contact your sales representative or a field
engineer.
Are you sure to continue adding [SB#$|IOU#$] to partition#$? [Y/N]:
Meaning:
This is a confirmation.
Corrective action:
Input "Y" if you continue. Input "N" if you don't continue.