W_00246
The %aa firmware update has been failed. Please retry to update the firmware. After Maintenance
completion, Check the System Event Log Window to refer to the error details.
Meaning:
The %aa firmware update process has terminated abnormally.
Corrective action:
This window is displayed again when the [OK] button is clicked. Execute the firmware update process again.
If the same event recurs, complete the replacement work and then check the system event log.
Severity:
Warning
E_00301
Maintenance cannot be continued because PSU could not be powered off.
Check the System Event Log Window to refer to the error details.
Meaning:
PSU power off process executed during PSU replacement in Hot System Maintenance has terminated
abnormally.
Corrective action:
The completion window appears when 'OK' in the dialog box is clicked. Check the system event log for any
errors.
If the cause is unknown, download the system event log, and contact your sales representative or a field
engineer.
Severity:
Error
E_00302
Maintenance cannot be continued because PSU could not be powered on.
Check the System Event Log Window to refer to the error details.
Meaning:
The PSU power on process that was executed when returning to the previous window by clicking the
[Previous] button, in PSU replacement of the Hot System Maintenance has terminated abnormally.
Corrective action:
The completion window appears when 'OK' in the dialog box is clicked. Check the system event log for any
errors. If the cause is unknown, download the system event log and contact your sales representative or a
field engineer.
Severity:
Error
E_00303
Maintenance cannot be continued because chassis status could not be retrieved. Check the System
Event Log Window to refer to the error details.
Meaning:
The acquisition of the system (chassis) power status in Hot System Maintenance / Warm System
Maintenance has terminated abnormally.
Corrective action:
The completion window appears when 'OK' in the dialog box is clicked. Check the system event log for any
errors. If the cause is unknown, download the system event log and contact your sales representative or a
field engineer.
Severity:
Error
E_00304
Maintenance cannot be continued because FAN Speed Mode could not be set to high-speed.
Please check System Event Log Window to refer to the error details.
Meaning:
The FAN high-speed setting process executed in Hot System Maintenance / Warm System Maintenance has
terminated abnormally.
Corrective action:
The completion window appears when 'OK' in the dialog box is clicked. Check the system event log for any
errors. If the cause is unknown, download the system event log and contact your sales representative or a
field engineer.
Severity:
Error