MMB Messages
19105
Adapter error (Reliability degraded)
2.0TB card
Meaning:
The reliability is degraded.
Corrective action:
It might be a temperature problem, power unit problem or life cycle problem etc...
Contact your sales representative or a field engineer.
Severity:
Warning
19106
Adapter error (Temperature above warning threshold)
2.0TB card
Meaning:
Temperature exceeded the upper warning threshold.
Corrective action:
Reduce the load of writing operations. Check the ambient temperature and system environment as well.
Severity:
Warning
19107
Adapter error (Adapter removed)
2.0TB card
Meaning:
Adapter is removed.
Corrective action:
Replace the PCIe-SSD card.
Severity:
Warning
19200
Adapter error (Temperature close to error threshold)
2.6TB card
Meaning:
Temperature closed the upper error threshold.
Corrective action:
Reduce the load of writing operations. Check the ambient temperature and system environment as well.
Severity:
Warning
19201
Adapter error (Temperature above error threshold)
2.6TB card
Meaning:
Temperature exceeded the upper error threshold.
Corrective action:
Reduce the load of writing operations. Check the ambient temperature and system environment as well.
Severity:
Warning
19202
Adapter error (Flashback error)
2.6TB card
Meaning:
Flashback error is occurred.
Corrective action:
Back up the data from the affected PCIe SSD. Replace the PCIe SSD as soon as possible, restore the data.
Severity:
Warning