• MultiTouchPad If you ordered a Barco display controller, it’s also in the box together with its accessories. A dedicated user guide is available on the system CD. Keep your original packaging. It is designed for this display and is the ideal protection during transport and storage.
Page 6
1. Welcome! K5902079 CORONIS UNITI 21/04/2015...
2. Parts, controls and connectors 2. PARTS, CONTROLS AND CONNECTORS Display front view Overview Image 2-1 Front view Right key I-Luminate/Left key Menu key Standby key Power status indicator light (Power On) Power status indicator light (Standby) Ambient light sensor I-Guard K5902079 CORONIS UNITI 21/04/2015...
2. Parts, controls and connectors Connector compartment cover open Image 2-3 Rear view with open connector compartment cover Display port connector Power connector Display port connector Not used USB upstream connector USB downstream connector USB downstream connector USB downstream connector Accessories Film clip The film clip can be used to hold a radiological film when using the I-Luminate function as a light box.
Page 10
2. Parts, controls and connectors MultiTouchPad The MultiTouchPad enables and controls SpotView. Image 2-5 MultiTouchPad K5902079 CORONIS UNITI 21/04/2015...
If you are using a Barco display controller, please consult the user guide delivered with it to do this. For a list of compatible display controllers, please refer to the latest version of the com- patibility matrix available on my.barco.com...
3. Display installation Unlocking the tilt mechanism In the factory, the tilt system in the display stand is locked with a red pin to prevent dam- age during transportation. You’ll have to remove this pin before adjusting your display position. Push the display against the buffer part to easily remove the pin.
3. Display installation To remove the pin: 1. Position the display with its rear side facing you. 2. While holding the display panel pushed down, pull out the red pin in the display stand. 3. Keep the pin in the dedicated hole in case the display needs to be shipped later. To retain the pin for possible future transportation, insert the short, red end of the pin back into the stand of your display.
3. Display installation Do not try to pivot your display when attached to the stand. Trying to do so AUTION could cause serious damage to your display and its stand. Connecting the signal cables To get access to the connectors, remove the connector compartment cover. See "Re- moving the connector compartment cover", page 9 .
Page 15
3. Display installation 2. Connect another head of the display controller to the other DisplayPort connector with one of the sup- plied DisplayPort cables. 3. Connect a PC USB downstream connector to the display’s USB upstream connector by means of the supplied USB 2.0 cable.
3. Display installation Communication with the display is possible via DisplayPort although it is recommended to use the USB upstream connector for faster communication. Connecting the power cable To connect the power cable to the display: 1. Connect the supplied external DC power supply to the +24 VDC power input of your Coronis Uniti display.
3. Display installation Warning:Fasten the power connector to your display with the screws provided at the sides of the con- nector. 2. Plug the other end of the external DC power supply into a grounded power outlet by means of the proper power cord delivered in the packaging.
3. Display installation 2. To remove the film clip, lift the front end or rear end of the clip. Mounting the MultiTouchPad To mount the MultiTouchPad 1. Connect the MultiTouchPad to one of the USB downstream connectors (using either those found in the cable compartment or on the right side of the display).
3. Display installation Routing the cables & Reattach the connector compartment cover To route the cables 1. Route all connected cables through the cable routing channel in the stand of your display. Tip: The cable straps at the inside of the connector compartment allow you to fix the cables for better shielding of the cables.
3. Display installation 3.10 Fixation of the foot on the desk Overview If you would like to attach the Coronis Uniti to a desk, the tilt & swivel foot has 4 screw holes (4x M4) to mount the foot on a desk. K5902079 CORONIS UNITI 21/04/2015...
3. Display installation 1. Drill four holes in the desk. (143) Fixation position: 4x M4 2. Fasten the foot on the desk with 4x M4 screws (length of the screws depending on the depth of the desk). 3.11 VESA-mount installation Use suitable mounting apparatus to avoid risk of injury.
Page 22
3. Display installation You should mount the panel in landscape position. Portrait position is pos- AUTION sible but not supported. To avoid muscle strain or back injury, use lifting aids and proper lifting tech- ARNING niques when removing or replacing. Overview The panel, standard attached to the tilt &...
Page 23
3. Display installation 4. Remove the two plastic covers. 5. Remove the 9 screws fixing the foot while supporting the foot. K5902079 CORONIS UNITI 21/04/2015...
Your Coronis Uniti display will be running in a basic video mode at a default refresh rate when first time starting up. If you are using a Barco display controller, please consult the dedicated user guide available on the system CD to install the drivers, software and documentation.
LCD displays use technology based on pixels. As a normal tolerance in the manufacturing of the LCD, a limited number of these pixels may remain either dark or permanently lit, without affecting the diagnostic performance of the product. To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels.
The ’MediCal QAWeb’ system offers online service for high-grade Quality Assurance, providing maximum diagnostic confidence and uptime. Barco recommends to install MediCal QAWeb Agent and apply the default QAWeb policy at least. This policy includes calibration on regular intervals. Connecting to MediCal QAWeb Server offers even more possibilities.
4. Daily operation To switch your display to Stand-by using the keys: Switching off the display can be done by: 1. Push the standby key shortly for three times. After the second push, the OSD message “Power off” appears on the display, this means the display will go in standby mode. As a result, the display will switch to stand-by mode and the power status indicator light is orange.
4. Daily operation I-Luminate is not available while the OSD menu is activated. Overview key icons Left, Right Menu Enter Cancel Standby (IEC 60417–5009) Overview of the functionality of the Left/Right keys Overview Left key Right key Behavior Push Push Cycle viewing mode between text, diagnostic Push No Push...
4. Daily operation Left key Right key Behavior No Push Push Enable OSD Left key Right key Menu Behavior No push Push No menu Cycle SoftGlow modes between task light, wall light, both, none. Push No push No menu Nothing Push Push No menu...
Page 30
4. Daily operation K5902079 CORONIS UNITI 21/04/2015...
5. Advanced operation 5. ADVANCED OPERATION OSD menu language About the OSD menu language By default, the OSD menu comes up in English. However, there’s a wide range of other languages avail- able for the OSD menu of your Coronis Uniti. To change the language of the OSD menu: 1.
5. Advanced operation Key indicator lights About the key indicator lights By default, after lighting up, the key indicator lights will dim again if no further actions are taken within the following 5 seconds. However, this behavior can be changed so that the key indicator lights are always on or always off.
By default, DPMS mode is enabled on your display, but it also needs to be activated on your workstation. To do this, go to the “Power options properties” window of your workstation. Barco recommends setting DPMS activation after 20 minutes of non-usage. When DPMS mode is enabled on your display, an additional OSD power saving function becomes available: hibernate.
5. Advanced operation Hibernate About hibernate Enabling hibernation will not only switch off the backlight but will also force the display to disable other functionalities so that power consumption is further reduced to a minimum. This happens after a specific period of time which can be manually adjusted.
5. Advanced operation 5.11 I-Luminate film position About the I-Luminate film position By default, the I-Luminate rectangle comes up in the top/center of the left part of the screen. This position can be changed to top/left or top/right corner of the left part of the screen or top/left, top/center or top/right corner of the right part of the screen.
5. Advanced operation 3. Enter the Color Presets submenu. 4. Select one of the available Color Presets and confirm. 5.14 Color temperature About color temperature: It is possible to change the color temperature of your display. Color temperature can only be changed on your display when color presets is set to user.
In short, the DICOM display function results in more visible grayscales in the images. Barco recommends selecting the DICOM display function for most medical viewing applications. K5902079 CORONIS UNITI 21/04/2015...
5. Advanced operation User This display function will be automatically selected when display functions are defined by MediCal QAWeb. Gamma 1.8 Select one of these display functions in case the display is to replace a CRT display with a gamma Gamma 2.2 of 1.8 or 2.2 respectively.
5. Advanced operation The available reading rooms for your Coronis Uniti are: CR/DR/ MAMMO Corresponds to light conditions in diagnostic reading rooms for computed radiology, digital radiology or mammography. This setting has the lowest maximum ambient light. CT/MR/NM Corresponds to light conditions in diagnostic reading rooms for computed tomography, magnetic resonance or nuclear medicine scans.
Embedded QA is not a replacement for the Barco MediCal QAWeb solution. Although Embedded QA is a reliable option to perform a simple calibration or compliance test, Barco still highly recommends MediCal QAWeb as the solution of choice for calibration and QA. Medical QAWeb brings many benefits such as centralized asset management, the ability to schedule tasks, remote man-...
5. Advanced operation Current DICOM Settings Display function Shows the current display function. Ambient Light Compensation Shows the ambient light compensation status. Reading room Shows the selected reading room. To retrieve the DICOM status report: 1. Bring up the OSD main menu. 2.
5. Advanced operation 5.21.6 DICOM error threshold About DICOM error threshold The threshold to define the DICOM compliance can be modified in steps of 5% starting from 5 to 30%. When the maximum deviation is not bigger than the selected threshold, the compliance check will be OK. To set the DICOM error threshold: 1.
5. Advanced operation Two Image Sources This mode is intended for displaying and manually configuring two connected video input signals (one on each display side). When selecting this mode, the video settings become available for the selected video input signal on each side of the display. Expert mode This mode is intended for displaying and manually configuring one or two connected video input...
5. Advanced operation 4. Select one of the available versions and confirm. To obtain full resolution (2100 x 2800) and full refresh rate (60Hz), DPCD V1.2 should be selected. 5.26 EDID format About EDID format The Coronis Uniti supports two EDID formats: E-EDID V1.4 and DisplayID V1.3 To select the EDID format 1.
5. Advanced operation 5.29 Display status About display status The Status submenu of the OSD menu provides info on the current status of your display (runtimes, tem- peratures, etc.), the status of the connected image sources (video encoding mode, timings, etc.), the current calibration status of your display (display function, luminance, ALC, etc.) and the status about activated connections.
Page 46
5. Advanced operation K5902079 CORONIS UNITI 21/04/2015...
6. Cleaning your display 6. CLEANING YOUR DISPLAY Cleaning instructions To clean the display Clean the display using a sponge, cleaning cloth or soft tissue, lightly moistened with a recognized clean- ing product for medical equipment. Read and follow all label instructions on the cleaning product. In case of doubt about a certain cleaning product, use plain water.
Page 48
6. Cleaning your display K5902079 CORONIS UNITI 21/04/2015...
7. Important information 7. IMPORTANT INFORMATION Safety information General recommendations Read the safety and operating instructions before operating the device. Retain safety and operating instructions for future reference. Adhere to all warnings on the device and in the operating instructions manual. Follow all instructions for operation and use.
7. Important information To fully disengage the power to the device, please disconnect the power cord from the AC inlet. Power cords: • Do not overload wall outlets and extension cords as this may result in fire or electric shock. •...
Page 51
(Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or hazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China, in the section “Limit Requirements of toxic substances in Electronic Information Products”.
“Electronic Information Products Pollution Control Labeling Standard” of Chinese Mainland, marked with the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses (please refer to the photo) is based on the “Standard of Electronic Information Products Environmental Friendly Use Period”...
7. Important information • Reorient or relocate the receiving antenna. • Increase the separation between the device and receiver. • Connect the device into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Page 54
7. Important information Electromagnetic immunity The Coronis Uniti is intended for use in the electromagnetic environment specified below. The customer or the user of the Coronis Uniti should assure that it is used in such an environment. Immunity test IEC 60601 Compliance level Electromagnetic environment –...
Page 55
7. Important information Immunity test Electromagnetic IEC 60601 Compliance level environment – Test levels guidance d = 1.2√P 80 MHz to 800 d = 2.3√P 800 MHz to 2.5 Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d...
7. Important information Rated maximum output Separation distance according to frequency of transmitter power of transmitter 150kHz to 80MHz 80MHz to 800MHz 800MHz to 2.5GHz d=1.2√P d=1.2√P d=2.3√P 0.01 0.12 0.12 0.23 0.38 0.38 0.73 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. These guidelines may not apply in all situations.
Page 57
7. Important information Indicates the device is approved according to the UL Demko regulations Indicates the device is approved according to the CCC regulations Indicates the device is approved according to the VCCI regulations Indicates the device is approved according to the KC regulations Indicates the device is approved according to the BSMI regulations Indicates the device is approved according to the PSE regulations Indicates the USB connectors on the device...
Barco software products are the property of Barco. They are distributed under copyright by Barco N.V. or Barco, Inc., for use only under the specific terms of a software license agreement between Barco N.V. or Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any form, is authorized.
Page 59
7. Important information Aspect ratio (H:V) Resolution 4200 x 2800 Pixel pitch 0.1686 mm Color imaging Gray imaging Color support Viewing angle (H, V) 178°, CR ≥ 10 Uniform Luminance Color PPU Technology (ULT) Per Pixel Uniformity (PPU) Yes, in color Ambient Light Compensation (ALC) Backlight Output Stabilization...
Open source license usage This product contains software components released under an Open Source license. A copy of the source code is available on request by contacting your Barco customer support representative. EACH SEPARATE OPEN SOURCE SOFTWARE COMPONENT AND ANY RELATED DOCUMENTA- TION ARE PROVIDED "AS IS"...