  • Page 1 CORONIS 3MP LED Display User Guide MDCG-3221 K5902060/01 28/02/2014...
  • Page 2 Barco nv President Kennedypark 35, 8500 Kortrijk, Belgium Phone: +32 56.23.32.11 Fax: +32 56.26.22.62 Support: www.barco.com/esupport Visit us at the web: www.barco.com Printed in Belgium...
  • Page 3: Table Of Contents

    Table of contents TABLE OF CONTENTS 1. Welcome! ..................3 About the product .................... . 3 Symbols .
  • Page 4 Table of contents 8. Important information ................35 Safety information.................... . 35 Environmental information ..
  • Page 5: Welcome

    Using energy-efficient LED backlights, Barco’s CORONIS 3MP LED Display is as low in power consump- tion as it is high in brightness. Additionally, Barco’s LED backlights are mercury-free, produce less heat, and last longer. This allows Barco to guarantee a 5-year backlight warranty.
  • Page 6: What's In The Box

    • an external power supply If you ordered a Barco display controller, it’s also in the box together with its accessories. A dedicated user guide is available on the system CD. Keep your original packaging. It is designed for this display and is the ideal protection during transport and storage.
  • Page 7: Parts, Controls And Connectors

    2. Parts, controls and connectors 2. PARTS, CONTROLS AND CONNECTORS Display front view Overview Image 2-1 Front view Left key Power LEDs Right key Ambient light sensor Menu key Bottom downstream USB Standby key K5902060 CORONIS 3MP LED DISPLAY 28/02/2014...
  • Page 8: Display Rear View

    2. Parts, controls and connectors Display rear view Connector compartment cover closed Image 2-2 Rear view with closed connector compartment cover Connector compartment cover Foot lock clip Cable duct Tilt & swivel foot K5902060 CORONIS 3MP LED DISPLAY 28/02/2014...
  • Page 9 2. Parts, controls and connectors Connector compartment cover open Image 2-3 Rear view with open connector compartment cover +24 VDC power input Ethernet connector (see note below) +5 VDC, 0.5A power output USB upstream connector DisplayPort video input USB downstream connector DVI video input The Ethernet connection is used for maintenance purposes and is not supported for user application.
  • Page 10 2. Parts, controls and connectors K5902060 CORONIS 3MP LED DISPLAY 28/02/2014...
  • Page 11: Display Installation

    Prior to installing your CORONIS 3MP LED Display and connecting all necessary cables, make sure to have a suitable display controller physically installed in your computer. If you are using a Barco display controller, please consult the user guide delivered with it to do this.
  • Page 12: Removing The Connector Compartment Cover

    3. Display installation 3. To change from portrait to landscape, turn the panel counterclockwise. 4. To change from landscape to portrait, turn clockwise. If, after installing the display of the system, you change the panel orientation while an image is on the screen, the result depends on the graphic board and the resolution of the image.
  • Page 13 3. Display installation 1. Connect the DVI or DP of the display controller to the DVI or DP connector of the display. 2. If you want to make use of the display’s USB upstream connector, connect a PC USB downstream connector to the display’s USB upstream connector.
  • Page 14: Routing The Cables & Reattach The Connector Compartment Cover

    3. Display installation Routing the cables & Reattach the connector compartment cover To route the cables 1. Route all connected cables through the cable routing channel in the stand of your display. Tip: The cable straps at the inside of the connector compartment allow you to fix the cables for better shielding of the cables.
  • Page 15 3. Display installation Use an arm that is approved by VESA (according to the VESA 100 mm stan- ARNING dard). Use an arm that can support the weight of the display. Refer to the technical specifica- tions of this display for the applicable weight. Overview The panel, standard attached to the tilt &...
  • Page 16: First Time Starting Up

    Your CORONIS 3MP LED Display will be running in a basic video mode at a default re- fresh rate when first time starting up. If you are using a Barco display controller, please consult the user guide delivered with it to install the drivers, software and documenta- tion.
  • Page 17: Daily Operation

    LCD displays use technology based on pixels. As a normal tolerance in the manufacturing of the LCD, a limited number of these pixels may remain either dark or permanently lit, without affecting the diagnostic performance of the product. To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels.
  • Page 18: Key Indicator Lights

    The ’MediCal QAWeb’ system offers online service for high-grade Quality Assurance, providing maximum diagnostic confidence and uptime. Barco recommends to install MediCal QAWeb Agent and apply the default QAWeb policy at least. This policy includes calibration on regular intervals. Connecting to MediCal QAWeb Server offers even more possibilities.
  • Page 19: Bringing Up The Osd Menus

    4. Daily operation Bringing up the OSD menus How to bring up the OSD menus The OSD menu allows you to configure different settings to make your CORONIS 3MP LED Display fit your needs within your working environment. Also, you can retrieve general information about your display and its current configuration settings through the OSD menu.
  • Page 20 4. Daily operation Cancel Standby (IEC 60417–5009) K5902060 CORONIS 3MP LED DISPLAY 28/02/2014...
  • Page 21: Advanced Operation

    5. Advanced operation 5. ADVANCED OPERATION OSD menu language About the OSD menu language By default, the OSD menu comes up in English. However, there’s a wide range of other languages avail- able for the OSD menu of your CORONIS 3MP LED Display. To change the language of the OSD menu: 1.
  • Page 22: Key Indicator Lights

    By enabling the Ethernet over USB, you allow the internal CORONIS 3MP LED Display processor to communicate directly over USB with the connected PC. Enabling the Ethernet over USB is only recommended when you are using a non-Barco display controller. If you are using a Barco display controller, this communication will automatically be done over the connected video cable(s).
  • Page 23: Usb

    Please note that a connection from a PC USB downstream connector to the display’s USB upstream connector is required to be able to use this functionality. Enabling the USB endpoint is only recommended when you are using a non-Barco dis- play controller. If you are using a Barco display controller, this communication will au- tomatically be done over the connected video cable(s).
  • Page 24: Hibernate

    5. Advanced operation Hibernate About hibernate Enabling hibernation will not only switch off the backlight but will also force the display to disable other functionalities so that power consumption is further reduced to a minimum. This happens after a specific period of time which can be manually adjusted.
  • Page 25: Display Functions

    In short, the DICOM display function results in more visible grayscales in the images. Barco recommends selecting the DICOM display function for most medical viewing applications. User This display function will be automatically selected when display functions are defined by MediCal...
  • Page 26: Ambient Light Compensation (Alc)

    5. Advanced operation 2. Navigate to the Configuration > Calibration menu. 3. Enter the Display Function submenu. 4. Select one of the available display functions and confirm. 5.13 Ambient Light Compensation (ALC) About ALC Ambient Light Compensation (ALC) can only be enabled on your display when the DI- COM display function is selected.
  • Page 27: Continuous Alc

    5. Advanced operation Staff Office Corresponds to light conditions in office rooms. Clinical Viewing Room Corresponds to light conditions in diagnostic reading rooms for clinical viewing. Emergency Room Corresponds to light conditions in emergency rooms. Operating Room Corresponds to light conditions in operating rooms. This setting has the highest maximum ambient light.
  • Page 28: Display Orientation

    5. Advanced operation 5.17 Display orientation About Display orientation Your display automatically detects its physical orientation (portrait or landscape) and, by default, automat- ically adjusts the image orientation to this. This means that when your display is physically rotated, the image will rotate along.
  • Page 29: Grayscale Conversion Modes

    HDR1). This mode is usually used on color displays. Dual 10 (only with Barco display controller) Dual 10 is a Barco specific 10-bit video encoding mode which is usually used on grayscale displays and which allows full refresh rate.
  • Page 30: Edid Timings

    5. Advanced operation 5.21 EDID timings About EDID timings Following EDID timings are available for your CORONIS 3MP LED Display: Refresh Rate Allows to manually select the refresh rate of the image source video input signal depending on the maximum refresh rate of the display controller connected to your display.
  • Page 31: Repackaging Instructions

    6. Repackaging instructions 6. REPACKAGING INSTRUCTIONS Before repacking the display, follow the instruction to replace the protection ARNING buffer to prevent damage to the display. Overview of the packaging Image 6-1 Packaging Bottom box Box (Power supply, cables) Bottom buffer Top buffer K5902060 CORONIS 3MP LED DISPLAY 28/02/2014...
  • Page 32: Replacing The Protection Buffer

    6. Repackaging instructions Top box Protection buffer Display Display controller box Replacing the protection buffer How to replace the protection buffer 1. Place the display on a stable surface. 2. Put the display in the lowest position and fasten the height mechanism, see "Unlocking the height mech- anism", page 9 .
  • Page 33: Repacking Your Display

    6. Repackaging instructions Repacking your display How to repack your display 1. Place the empty bottom box on a stable surface. 2. Place the bottom buffer in the box. 3. Put the display together with the protection buffer (see "Replacing the protection buffer", page 30) in the dedicated cavity of the bottom buffer.
  • Page 34 6. Repackaging instructions K5902060 CORONIS 3MP LED DISPLAY 28/02/2014...
  • Page 35: Cleaning Your Display

    7. Cleaning your display 7. CLEANING YOUR DISPLAY Cleaning instructions To clean the display Clean the display using a sponge, cleaning cloth or soft tissue, lightly moistened with a recognized clean- ing product for medical equipment. Read and follow all label instructions on the cleaning product. In case of doubt about a certain cleaning product, use plain water.
  • Page 36 7. Cleaning your display K5902060 CORONIS 3MP LED DISPLAY 28/02/2014...
  • Page 37: Important Information

    8. Important information 8. IMPORTANT INFORMATION Safety information General recommendations Read the safety and operating instructions before operating the device. Retain safety and operating instructions for future reference. Adhere to all warnings on the device and in the operating instructions manual. Follow all instructions for operation and use.
  • Page 38: Environmental Information

    8. Important information Power cords: • Utilize a UL-listed detachable power cord, 3-wire, type SJ or equivalent, 18 AWG min., rated 250 V min., provided with a hospital-grade type plug 5-15P configuration for 120V application, or 6-15P for 240V application. •...
  • Page 39 (Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or hazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China, in the section “Limit Requirements of toxic substances in Electronic Information Products”.
  • Page 40: Regulatory Compliance Information

    “Electronic Information Products Pollution Control Labeling Standard” of Chinese Mainland, marked with the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses (please refer to the photo) is based on the “Standard of Electronic Information Products Environmental Friendly Use Period”...
  • Page 41: Emc Notice

    8. Important information to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •...
  • Page 42 8. Important information If this equipment does cause harmful interference to, or suffer from harmful interference of, surrounding equipment, the user is encouraged to try to correct the interference by one or more of the following mea- sures: • Reorient or relocate the receiving antenna or equipment. •...
  • Page 43 8. Important information Immunity test Electromagnetic IEC 60601 Compliance level environment – Test levels guidance part of the CORONIS IEC 61000-4-3 80 MHz to 2.5 GHz 3 V/m 3MP LED Display, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
  • Page 44: Explanation Of Symbols

    8. Important information These guidelines may not apply in all situations. Electromagnetic propagation is af- fected by absorption and reflection from structures, objects and people. Recommended separation distance The CORONIS 3MP LED Display is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
  • Page 45 8. Important information Indicates the device is approved according to the UL regulations Indicates the device is approved according to the UL regulations for Canada and US Indicates the device is approved according to the UL Demko regulations Indicates the device is approved according to the CCC regulations Indicates the device is approved according to the VCCI regulations Indicates the device is approved according to the KC regulations Indicates the device is approved according to the BSMI regulations...
  • Page 46 8. Important information Indicates this device must not be thrown in the trash but must be recycled, according to the European WEEE (Waste Electrical and Electronic Equipment) directive Indicates Direct Current (DC) Indicates Alternating Current (AC) Stand-by Equipotentiality Symbols on the box On the box of the device, you may find the following symbols (nonrestrictive list): Indicates a medical device that can be broken or damaged if not handled carefully when being...
  • Page 47: Legal Disclaimer

    Barco software products are the property of Barco. They are distributed under copyright by Barco N.V. or Barco, Inc., for use only under the specific terms of a software license agreement between Barco N.V. or Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any form, is authorized.
  • Page 48 8. Important information Uniform Luminance Technology (ULT) Per Pixel Uniformity (PPU) Ambient Light Compensation (ALC) Backlight Output Stabilization (BLOS) I-Guard Maximum luminance 1700 cd/m² typical DICOM calibrated luminance 600 cd/m² (ULT off) Contrast ratio (ULT off) 1330 Response time (Tr + Tf) 40 ms Scanning frequency (H;...
  • Page 49: Open Source License Information

    Open source license usage This product contains software components released under an Open Source license. A copy of the source code is available on request by contacting your Barco customer support representative. EACH SEPARATE OPEN SOURCE SOFTWARE COMPONENT AND ANY RELATED DOCUMENTA- TION ARE PROVIDED "AS IS"...

Table of Contents