Table of contents 1 Welcome!.......................................... 5 What's in the box ....................................6 At a glance ......................................6 Compatible Barco system components..........................9 2 Installation and setup..................................11 Single workstation setup................................12 Dual workstation setup with KVM switch ...........................13 QAWeb registration ..................................16 VESA-mount installation ................................16 VESA-mount installation in portrait mode .........................18...
Page 4
6 Repackaging instructions ................................45 Repackaging instructions ................................46 7 Important information..................................51 Safety information...................................52 Cybersecurity ....................................53 Environmental information.................................54 Regulatory compliance information ............................55 EMC notice ......................................57 Explanation of symbols................................59 Legal disclaimer....................................63 Open source license information ............................63 Technical specifications................................64 R5913350 /05 Nio Fusion 12MP...
Welcome! What's in the box ..........................6 At a glance.............................6 Compatible Barco system components.....................9 R5913350 /05 Nio Fusion 12MP...
• Cables for Mains, Video and USB If you ordered a Barco MXRT display controller, it is also in the box together with its accessories. A dedicated user guide is available on the documentation disc. Keep your original packaging. It is designed for this display and is the ideal protection during transport and storage.
Page 7
10. Stand locking mechanism Connectors One USB connector is available on the side of the display. To access the bottom connectors, gently pull the bottom of the connector cover away from the display. Image 1–2 R5913350 /05 Nio Fusion 12MP...
Page 8
After unpacking, you can safely tilt and swivel the display to your preferred position. Image 1–4 To adjust the height of the display, first move the slider at the back of the stand to the unlock position. Then you can raise or lower the display as desired. R5913350 /05 Nio Fusion 12MP...
1.3 Compatible Barco system components Overview Following Barco components are compatible with your Nio Fusion 12MP display: • QAWeb Enterprise version 2.5 or later, or MediCal QAWeb version 1.13.20 or later •...
Connect the supplied mains cable to a grounded power outlet. For a list of compatible display controllers, please refer to the compatibility matrix available on my.barco.com (MyBarco > My Support > Healthcare > Compatibility Matrices > Barco Systems Compatibility Matrices)
Your display will be running in a basic video mode at a default refresh rate when first time starting up. Install the MXRT driver and Intuitive Workflow Tools When using a Barco MXRT display controller, install the MXRT driver and Intuitive Workflow Tools on the connected workstation. Barco’s Intuitive Workflow Tools are designed to increase visibility of subtle details, improve focus during reading sessions, and accelerate workflow.
Page 14
STATION 1 STATION 2 Image 2–4 For a list of compatible display controllers, please refer to the compatibility matrix available on my.barco.com (MyBarco > My Support > Healthcare > Compatibility Matrices > Barco Systems Compatibility Matrices) R5913350 /05 Nio Fusion 12MP...
Page 15
Your display will be running in a basic video mode at a default refresh rate when first time starting up. Install the MXRT driver and Intuitive Workflow Tools When using a Barco MXRT display controller, install the MXRT driver and Intuitive Workflow Tools on both connected workstations. Barco’s Intuitive Workflow Tools are designed to increase visibility of subtle details, improve focus during reading sessions, and accelerate workflow.
Learn more at www.barco.com/qaweb. To register your display system to your QAWeb Enterprise organization, the QAWeb Enterprise Agent must be installed and running on your workstation and it must be able to communicate with the QAWeb Enterprise cloud service.
Page 17
4. Push the VESA mount cover to the left and release the cover on the left with a flathead screwdriver. Image 2–7 5. Rotate the VESA mount cover to uncover the screws fixing the panel to the stand. R5913350 /05 Nio Fusion 12MP...
2.5 VESA-mount installation in portrait mode Introduction By default, your Nio Fusion 12MP display is mounted in landscape position but it can also be used in portrait position. This section explains how to install and use the display in portrait orientation. Carefully follow the instructions hereafter to ensure proper product operation and to avoid physical damage to the product.
Page 19
5. In the EDID timings menu of the OSD, change the resolution to 12MP. For instructions, see “EDID timings”, page 6. Rotate the Windows desktop in portrait mode. From Windows 7 onwards, an “Orientation” option is available in the display settings. For Windows 10, see https://support.microsoft.com/en-us/help/4027186/windows-10-change-screen-orientation. R5913350 /05 Nio Fusion 12MP...
Page 20
Installation and setup R5913350 /05 Nio Fusion 12MP...
LCD displays use technology based on pixels. As a normal tolerance in the manufacturing of the LCD, a limited number of these pixels may remain either dark or permanently lit, without affecting the diagnostic performance of the product. To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels.
“SoftGlow Task light”, page 28 “SoftGlow Wall light”, page The SoftGlow lights can also be enabled and configured in the Intuitive Workflow Tools. See the Barco “Display Controller and Intuitive Workflow Tools” user guide on the included documentation CD, or at www.barco.com/support.
About the KVM switch The Nio Fusion 12MP can be used in a dual workstation setup with KVM switch. This allows the display to be connected to two different workstations and control both with a single keyboard and mouse connected to the display.
Certain OSD menu settings affecting calibration can be managed by QAWeb. Manually changing these settings in the OSD menu is still possible but the changes will be overwritten at each sync with QAWeb. The OSD menu can also be locked/unlocked by QAWeb. R5913350 /05 Nio Fusion 12MP...
About the OSD menu language By default, the OSD menu comes up in English. However, there’s a wide range of other languages available for the OSD menu of your Nio Fusion 12MP. To change the language of the OSD menu: Bring up the OSD main menu.
“SoftGlow light mode switching”, page The SoftGlow lights can also be enabled and configured in the Intuitive Workflow Tools. See the Barco “Display Controller and Intuitive Workflow Tools” user guide on the included documentation CD, or at www.barco.com/support. To adjust the SoftGlow Task light brightness Bring up the OSD main menu.
Advanced operation The SoftGlow lights can also be enabled and configured in the Intuitive Workflow Tools. See the Barco “Display Controller and Intuitive Workflow Tools” user guide on the included documentation CD, or at www.barco.com/support. To adjust the SoftGlow Wall light brightness Bring up the OSD main menu.
4.9 Luminance target About the luminance target The luminance target of your Nio Fusion 12MP is adjustable over a predefined range. When you change the luminance target, the display will adjust its backlight to reach the target. To set the luminance target: Bring up the OSD main menu.
To select a color space 1. Bring up the OSD main menu. 2. Navigate to the Configuration > Calibration menu. 3. Enter the Color Space submenu. 4. Select one of the available color space settings and confirm. R5913350 /05 Nio Fusion 12MP...
Please note that text mode is not persistent, once powered off, the unit will restart in diagnostic mode. The diagnostic mode should always be selected when the Nio Fusion 12MP is intended to be used in a diagnostic environment.
These parameters are stored in your display and determine the preset ambient light correction value to take into account to recalculate the DICOM display function when Ambient Light Compensation (ALC) is enabled. Please refer to “Ambient Light Compensation (ALC)”, page 33 to enable ALC. R5913350 /05 Nio Fusion 12MP...
Embedded QA is not a replacement for the Barco QAWeb solution. Although Embedded QA is a reliable option to perform a simple calibration or compliance test, Barco still highly recommends QAWeb as the solution of choice for calibration and QA. QAWeb brings many benefits...
Bring up the OSD main menu. Navigate to the Configuration > Calibration > Embedded QA menu. Select DICOM Compliance Check to start the compliance check. Warning: Pressing a key during the compliance check will abort the check. R5913350 /05 Nio Fusion 12MP...
Image scaling is only possible when the resolution of your display’s video input signal is less than or equal to half the maximum resolution of the display. R5913350 /05 Nio Fusion 12MP...
About the KVM switch The Nio Fusion 12MP can be used in dual workstation setup with KVM switch. This allows the display to be connected to two different workstations and control both with a single keyboard and mouse connected to the display.
Select one of the available color conversion modes and confirm. 4.23 DisplayPort standard version About DisplayPort standard version The Nio Fusion 12MP supports 2 DisplayPort standard versions: DP V1.1 and DP V1.2, the latter providing a higher video bandwidth. R5913350 /05...
4.24 EDID format About EDID format Following EDID formats are available for your Nio Fusion 12MP: • EDID 1.4: Factory default setting and advised for a single workstation setup (see “Single workstation setup”, page...
4.28 SteadyColor™ About SteadyColor Barco’s SteadyColor technology was created to achieve consistency and perceptual linearity in the display of color images. With multiple internal sensors, the display parameters are constantly monitored and adjusted to ensure that the perceptual difference between colors is proportional with their Digital Driving Level (DDL) difference.
Page 41
Navigate to the Maximum Luminance demo submenu and confirm. The maximum luminance demo is activated. Press the jog dial to manually cancel the maximum luminance demo, or wait for 60 seconds after which the demo is automatically cancelled. R5913350 /05 Nio Fusion 12MP...
Do not use sharp objects such as paperclips or tweezers to avoid damage to the LCD. CAUTION: Do not apply or spray liquid directly to the display as excess liquid may cause damage to internal electronics. Instead, apply the liquid to a cleaning cloth. R5913350 /05 Nio Fusion 12MP...
Image 6–1 2. Place the display in the bottom buffer on a stable surface. Caution: It takes 2 persons to safely execute this action. Image 6–2 3. Insert the rear buffer in the bottom buffer. R5913350 /05 Nio Fusion 12MP...
Page 47
Repackaging instructions Image 6–3 4. Position the front buffer. Image 6–4 5. Slide the accessory box(es) and all cables in the dedicated cavities. R5913350 /05 Nio Fusion 12MP...
Page 48
Repackaging instructions Image 6–5 6. Slide the display and the accessories in the box. Image 6–6 7. Close and seal the box. R5913350 /05 Nio Fusion 12MP...
Mains lead protection (U.S.: Power cord): Power cords should be routed so that they are not likely to be walked upon or pinched by items placed upon or against them, paying particular attention to cords at plugs and receptacles. R5913350 /05 Nio Fusion 12MP...
7.2 Cybersecurity Hospital IT security To prevent unauthorized access to the device, the organization incorporating the Nio Fusion 12MP in their IT network shall have the necessary state-of-the-art policies, processes, standards and other security measures in place to incorporate, support and protect the device into the IT network. This shall include the application of risk management (e.g.
Electronic Products ” (Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or hazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China, in the section “Limit Requirements of toxic substances in Electronic Information Products”.
Mainland, marked with the Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses (please refer to the photo) is based on the “General guidelines of environment-friendly use period of electronic information products” of Chinese Mainland.
Page 56
The manufacturing country of the product is indicated on the product label (“Made in …”). Importers contact information To find your local importer, contact one of Barco’s regional offices via the contact information provided on our website (www.barco.com). FCC class B This device complies with Part 15 of the FCC Rules.
Electromagnetic emissions The Nio Fusion 12MP is intended for use in the electromagnetic environment specified below. The customer or the user of the Nio Fusion 12MP should assure that it is used in such an environment. Electromagnetic environment – Compliance...
Page 58
GMRS 460, FM ± 5 kHz FRS 460 deviation 1 kHz sine 704 – 787 LTE Band Pulse 13, 17 modulation 217 Hz Nio Fusion 12MP doesn’t contain components that are susceptible to magnetic fields. R5913350 /05 Nio Fusion 12MP...
Indicates the device is approved according to the UL regulations Indicates the device is approved according to the UL regulations for Canada and US Indicates the device is approved according to the UL regulations for Canada and US E352529 R5913350 /05 Nio Fusion 12MP...
Page 60
IS 13252 (Part 1) IEC 60950-1 R-xxxxxxxx www.bis.gov.in Indicates the device is approved according to the INMETRO regulations. Indicates the USB connectors on the device. Indicates the DisplayPort connectors on the device. Indicates the legal manufacturer. R5913350 /05 Nio Fusion 12MP...
Page 61
Indicates this device must not be thrown in the trash but must be recycled, according to the European WEEE (Waste Electrical and Electronic Equipment) directive. Indicates Direct Current (DC). Indicates Alternating Current (AC). Values for xx and yy can be found in the technical specifications paragraph. R5913350 /05 Nio Fusion 12MP...
Page 62
Indicates the range of atmospheric pressure to which the device can be safely 106 kPa exposed when being stored. 50 kPa Values for xx and yy can be found in the technical specifications paragraph. R5913350 /05 Nio Fusion 12MP...
Barco software products are the property of Barco. They are distributed under copyright by Barco NV or Barco Inc., for use only under the specific terms of a software license agreement between Barco NV or Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any form, is authorized.
Barco whatsoever. You further acknowledge that any such additions, changes or modifications may impair the ability of Barco – at Barco’s sole discretion - to continue to provide service, warranties, software updates, fixes, maintenance, access or such similar abilities, without any recourse or claim towards Barco whatsoever.
Page 65
CAN/CSA C22.2 No. 60950-1-07:2014 IEC 60601-1:2005 + A1:2012 EN 60601-1:2006 + A1:2013 + A12:2014 ANSI/AAMI ES 60601-1:2005 + R1:2012 CAN/CSA C22.2 No. 60601-1:2014 EMI specific: IEC 60601-1-2:2014 (ed4) EN 60601-1-2:2015 (ed4) FCC part 15 Class B R5913350 /05 Nio Fusion 12MP...
Page 66
Storage temperature -20 °C to 60 °C Operating humidity 10% to 70% (non-condensing) Storage humidity 10% to 70% (non-condensing), max. 70% at max. 40 °C Operating pressure 62 kPa minimum Storage pressure 50 to 106 kPa R5913350 /05 Nio Fusion 12MP...
Page 67
Important information Relation of storage and operating humidity and temperature Image 7–1 R5913350 /05 Nio Fusion 12MP...
Page 68
Important information R5913350 /05 Nio Fusion 12MP...
Need help?
Do you have a question about the MDNC-12130 and is the answer not in the manual?
Questions and answers