If Option 1 Slot; If Option 2 Slot - B&R Industries MAPPC900-ENG User Manual

Panel pc 900
Table of Contents

Advertisement

2.4.18 IF option 1 slot

The Panel PC system units include 2 slots for interface options.
The following table lists the interface options that can be used in the IF option 1 slot.
Model number
Short description
Interface option
5AC901.I485-00
RS232/422/485 interface option; for installation in an
1)
APC910 or PPC900
5AC901.ICAN-00
CAN interface option; for installation in an APC910 or
1)2)
PPC900
5AC901.IHDA-00
Audio interface option, connection for 1x MIC, 1x Line IN,
1x Line OUT, for installation in an APC910
5AC901.IRDY-00
Ready relay interface option; for installation in an APC910
or PPC900
5AC901.IUPS-00
UPS interface option; for installation in an APC910; for a
3)
4.5 Ah battery.
5AC901.IUPS-01
UPS interface option; for installation in an APC910; for a
4)
2.2 Ah battery.
1)
If IF options 5AC901.I458-00 and 5AC901.ICAN-00 are used simultaneously, 5AC901.ICAN-00 should be installed in the IF option 1 slot and 5AC901.I485-00
should be installed in the IF option 2 slot.
2)
It is not possible to operate two 5AC901.ICAN interface options (in the IF option 1 and IF option 2 slots) at the same time.
3)
The 5AC901.IUPS-00 UPS IF option is only permitted to be operated with the 5AC901.BUPS-00 battery unit!
4)
The 5AC901.IUPS-01 UPS IF option is only permitted to be operated with the 5AC901.BUPS-01 battery unit!
Information:
For information about installing or replacing an interface option, please refer to the section "Installing
the interface option" on page 141.

2.4.19 IF option 2 slot

The Panel PC system units include 2 slots for interface options.
The following table lists the interface options that can be used in the IF option 2 slot.
Model number
Short description
Interface option
5AC901.I485-00
RS232/422/485 interface option; for installation in an
1)
APC910 or PPC900
5AC901.ICAN-00
CAN interface option; for installation in an APC910 or
1)2)
PPC900
5AC901.ISRM-00
SRAM interface option, 2 MB; for installation in an
APC910 or PPC900
5AC901.IRDY-00
Ready relay interface option; for installation in an APC910
or PPC900
1)
If IF options 5AC901.I458-00 and 5AC901.ICAN-00 are used simultaneously, 5AC901.ICAN-00 should be installed in the IF option 1 slot and 5AC901.I485-00
should be installed in the IF option 2 slot.
2)
It is not possible to operate two 5AC901.ICAN interface options (in the IF option 1 and IF option 2 slots) at the same time.
Information:
For information about installing or replacing an interface option, please refer to the section "Installing
the interface option" on page 141.
Panel PC 900 User's Manual V1.05
IF option 1 slot
IF Option 1
Table 48: IF option 1 slot
IF option 2 slot
IF Option 1
Table 49: IF option 2 slot
Technical data • Complete system
IF Option 2
IF Option 2
53

Advertisement

Table of Contents
loading

Table of Contents