Installation • Installation

1.8 Replacing the fan kit

1. Disconnect the power supply to the B&R industrial PC (unplug the power cable!). Isolate from all potential
sources of electrical power!
2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body.
3. Press in the indicated latching mechanisms ➀ while pulling out the fan kit ➁ at the same time.
4. A new fan kit can now be installed. Align the fan kit parallel to the Panel PC and press it in until it latches.
Make sure the fan kit is inserted so that the connections match up.
5. If a fan kit is being installed for the first time (i.e. fan kit previously not used in device), then it must still be
programmed. To do so, follow the instructions in the "Programming fan kit data" section.
If a fan kit has been removed from the device and is not being replaced, then its data must be deleted. To do
so, follow the instructions in the "Deleting fan kit data" section.
Information:
If a fan kit has been replaced, then an incorrect serial number will be displayed. To display the
correct serial number, the fan kit data must be deleted and reprogrammed.
6. After the fan kit has been programmed, the BIOS default values must be loaded and the settings saved. For
additional information, see "Save & Exit" on page 223.
Programming fan kit data
Information:
If a fan kit is being installed for the first time (i.e. fan kit previously not used in device), then it must
still be programmed.
1. Boot the B&R industrial PC and type the following on the command line:
m txcs vc i fa n fs et - Checks whether the fan kit has already been programmed
2. If the fan kit has not yet been programmed, this can be done by typing in the following:
m txcsv c u fa nf s et " f n" - The path of the file and filename must be specified in place of "fn".
Deleting fan kit data
Information:
If a fan kit has been removed from the device and is not being replaced, then its data must be deleted.
1. Boot the B&R industrial PC and type the following on the command line:
m txcs vc i fa n fs et - Checks whether the fan kit has already been programmed
2. Since a fan kit was already installed, its data must be deleted. This is done by typing the following on the
command line:
m txcsv c d fa nf s et - Deletes the data of the previously installed fan kit
146
Figure 77: Pressing in the latching mechanism