5Ac901.Iups-01 - B&R Industries MAPPC900-ENG User Manual

Panel pc 900
Table of Contents

Advertisement

3.10.3 5AC901.IUPS-01

3.10.3.1 General information
The 5AC901.IUPS-01 UPS IF option, together with the 5AC901.BUPS-01 battery unit, allows the B&R Industrial
PC to be shut down without any loss of data during a power failure.
The 5AC901.IUPS-01 UPS interface option can only be operated in the IF option 1 slot.
Warning!
The 5AC901.IUPS-01 UPS IF option is only permitted to be operated with the 5AC901.BUPS-01 battery
unit!
Information:
If the system is in standby mode (S5: Soft-off mode or S4: Hibernation mode - suspend-to-disk), then
the internal UPS interface option charges the connected battery unit. The system's internal power
supplies are active during this procedure. This allows various actions to be completed (e.g. opening
the tray of the slide-in DVD drive).
3.10.3.2 Order data
Model number
Short description
Uninterruptible power supplies
5AC901.IUPS-01
UPS interface option; for installation in an APC910 or PPC900;
for 2.2 Ah battery
Required accessories
Uninterruptible power supplies
5AC901.BUPS-01
Battery unit 2.2 Ah; for UPS 5AC901.IUPS-01
5CAUPS.0005-01
UPS cable 0.5 m; for 5AC901.IUPS-00 and 5AC901.IUPS-01
UPS
5CAUPS.0010-01
UPS cable 1 m; for 5AC901.IUPS-00 and 5AC901.IUPS-01 UPS
5CAUPS.0030-01
UPS cable 3 m; for 5AC901.IUPS-00 and 5AC901.IUPS-01 UPS
3.10.3.3 Technical data
Information:
The following characteristics, features and limit values only apply to this accessory and can deviate
from those specified for the complete system. The data specifications for the complete system take
precedence over those of individual components.
Product ID
General information
B&R ID code
Certification
CE
cULus
cULus HazLoc Class 1 Division 2
GOST-R
Electrical characteristics
Power consumption
Deep discharge protection
Short circuit protection
Battery charging data
Charging current
Environmental conditions
Temperature
Operation
Storage
Transport
Panel PC 900 User's Manual V1.05
Table 123: 5AC901.IUPS-01 - Order data
Table 124: 5AC901.IUPS-01 - Technical data
Technical data • Individual components
Figure
5AC901.IUPS-01
0xDF84
Yes
Yes
Yes
1)
Yes
Max. 25 watts at 0.9 A
Yes
Yes
2)
Typ. 0.88 A
0 to 55°C
3)
-20 to 60°C
-20 to 60°C
119

Advertisement

Table of Contents
loading

Table of Contents