Installing And Replacing The Slide-In Compact Drive - B&R Industries MAPPC900-ENG User Manual

Panel pc 900
Table of Contents

Advertisement

Installation • Installation

1.7 Installing and replacing the slide-in compact drive

Information:
The slide-in compact drive can only be replaced without removing the PPC from the control cabinet
if the wall is less than 5.5 mm thick. Steps 3, 4 and 11 are only necessary if the Panel PC is removed
from the cabinet.
1. Disconnect the power supply to the B&R industrial PC (unplug the power cable!). Isolate from all potential
sources of electrical power!
2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body.
3. Remove the Panel PC from the control cabinet. To do so, follow the steps in section "Installation Panel PC
900" on page 132 in reverse order.
4. Place the Panel PC on a clean, flat surface.
5. Remove the Torx screws (T10) indicated in the following image.
6. Tilt the cover plate forward and remove it by sliding it upward.
7. Free the plastic removal strip fastened to the side of the slide-in compact drive.
144
Figure 73: Removing the Torx screws
Figure 74: Removing the cover plate
Figure 75: Freeing the removal strip on the slide-in compact drive