2N Helios IP Verso Installation Manual page 84

Modular ip intercom
Hide thumbs Also See for Helios IP Verso:
Table of Contents

Advertisement

Legend
LAN
(PoE)
IN1
OUT1
RELAY1 RELAY1 terminals with accessible 30 V / 2 A AC/DC NO/NC contact
12V/2A External 12 V / 2 A DC supply terminals
GND
RESET
RGY
LINE
OUT
MIC
BUS
Device Restart
Press the RESET button shortly to restart the device.
Factory Reset
®
2N
Helios IP Verso is equipped with a RESET button. Press the button shortly (< 1
s) to restart the system without changing configuration.
Follow the instructions below to
Press and hold the RESET button.
Wait until the red and green LEDs on the device come on simultaneously (approx.
20 s).
Release the RESET button.
The device announces the current IP address via the loudspeaker connected
automatically.
Follow the instructions below to switch on the
Press and hold the REST button.
Wait until the red and green LEDs on the device come on simultaneously (approx.
20 s).
Wait until the red LED goes off (approx. 5 s).
Release the RESET button.
The following network parameters will be set after restart:
IP address: 192.168.1.100
®
2N
TELEKOMUNIKACE a.s., www.2n.cz
LAN (PoE according to 802.1af) connector
IN1 terminals for input in passive/ active mode (−30 V to +30 V DC)
OFF = open OR U
IN
ON = closed contact OR U
OUT1 terminals of active input for
electric lock connection 8 up to 12 V DC depending on power supply (PoE:
10 V; adaptor: power supply voltage minus 2 V), max 400 mA
Grounding terminal
RESET / FACTORY RESET button
LED indicators (red/green/yellow)
LINE OUT connector (1 V
MIC connector for microphone connection
®
2N
Helios IP Verso bus connector
> 1.5 V
< 1.5 V
IN
2N
®
Helios IP Security Relay
)
RMS
identify the current IP address
Static IP address
or
:
mode (DHCP OFF):
84

Hide quick links:

Advertisement

Table of Contents
loading