Accessing Live Video Feed in the Graphics Engine
Setting the Media Folder parameter on one of the Graphic Object layers to a DMX value of 255
will allow you to access input from video capture cards installed on your Axon unit.
There are 5 connectors on the input card, these connectors relate to the input and output of the
2 capture channels as well as a reference signal. Capture Stream 1, is available for use in folder
255, file 1. Capture Stream 2 is available for use in folder 255, file 2. These file and folders can
be used multiple times, on multiple layers, they are only referencing a live source.
The connector diagram below shows the position of Connectors for input 1, and input 2.
Note:
At times there can be a mismatch in the information set on the camera
and the information decoded for informational purposes. If the image
being captured is visible, but the information does not match, this is a
known issue across the video industry. The root cause is historical.
Axon HD Media Server User Manual
Axon HD Pro Live Video Input and Control
CHAPTER 3
19