System Operation Guidelines - Hypertherm Powermax30 XP Service Manual

Plasma arc cutting system
Hide thumbs Also See for Powermax30 XP:
Table of Contents

Advertisement

System operation guidelines

To achieve the highest level of performance:
Operate the system at an input power of 240 VAC whenever possible.
Avoid using an extension cord whenever possible.
If you must use an extension cord, use a heavy conductor cord of the shortest possible
length. See Extension cord recommendations on page 28.
If you are operating your system on a 120 V, 15 A circuit, do not set the amperage higher than 20 A. See Voltage
configurations on page 25.
For best results when operating your system on a 120 V, 15 A circuit:
Do not connect anything else that will draw power from the same circuit.
Be aware that extension cords can reduce the voltage to the machine from what is output by the circuit. This
reduction in power can impair cutting performance and increase the probability of tripping the circuit breaker.
Cutting a thicker workpiece with the general-purpose consumables requires a higher amperage setting. It is
preferable to operate on a higher rated circuit (240 V / 30 A) when cutting thicker metal. See Voltage configurations
on page 25.
Additional techniques to reduce the frequency of tripped circuit breakers include:
Turn down the amperage adjustment knob.
Avoid stretching the arc. Instead, drag the torch on the workpiece as explained in Edge start on a workpiece on
page 50.
Powermax30 XP Service Manual 808150 Revision 0
4 – Operation
47

Advertisement

Table of Contents
loading

Table of Contents