30.6 Sonar troubleshooting

Problems with the sonar and their possible causes and solutions are described here.
Scrolling image is not being displayed
Possible causes
Sonar disabled
Damaged cables
Damaged or fouled transducer
Wrong transducer fitted
SeaTalk
hs
/ RayNet network problem.
Software mismatch between equipment may
prevent communication.
No depth reading / lost bottom lock
Possible causes
Transducer location
Transducer angle
Transducer kicked-up
Power source insufficient
Damaged or fouled transducer
Damaged cables
398
Possible solutions
Select Enable Sonar from the Shortcuts page.
1.
Check that the transducer cable connector is fully inserted and locked in
position.
2.
Check the power supply cable and connectors for signs of damage or
corrosion, replace if necessary.
3.
With the unit turned on, try flexing the cable near to the display connector to
see if this causes the unit to re-boot/loose power, replace if necessary.
4.
Check the vessel's battery voltage, the condition of the battery terminals
and power supply cables, ensuring connections are secure, clean and free
from corrosion, replace if necessary.
5.
With the product under load, using a multi-meter, check for high voltage drop
across all connectors/fuses etc (this can cause the Fishfinder applications to
stop scrolling or the unit to reset/turn off), replace if necessary.
Check the condition of the transducer ensuring it is not damaged and is free from
debris/fouling, clean or replace as necessary.
Refer to
Chapter 33 Spares and accessories
• Check that the unit is correctly connected to the multifunction display or
Raymarine network switch. If a crossover coupler or other coupler cable /
adapter is used, check all connections ensuring connections are secure, clean
and free from corrosion, replace if necessary.
Ensure all Raymarine products contain the latest available software, check the
Raymarine website:
www.raymarine.com/software
Possible solutions
Check that the transducer has been installed in accordance with the instructions
provided with the transducer.
If the transducer angle is too great the beam can miss the bottom, adjust
transducer angle and recheck.
If the transducer has a kick-up mechanism, check that it has not kicked up due to
hitting an object.
With the product under load, using a multi-meter, check the power supply
voltage as close to the unit as possible to establish actual voltage when the
current is flowing. (Refer to
requirements.)
Check the condition of the transducer ensuring it is not damaged and is free
from debris / fouling.
1.
Check the unit's connector for broken or bent pins.
2.
Check that the cable connector is fully inserted into the unit and that the
locking collar is in the locked position.
3.
Check the cable and connectors for signs of damage or corrosion, replace
if necessary.
4.
With the unit turned on, try flexing the power cable near to the display
connector to see if this causes the unit to re-boot/loose power, replace
if necessary.
5.
Check the vessel's battery voltage, the condition of the battery terminals
and power supply cables, ensuring connections are secure, clean and free
from corrosion, replace if necessary.
for transducer compatibility.
for software compatibility.