SYNC (VIDEO SYNC IN)

The 4-pin 00B LEMO SYNC connector accepts timecode, genlock, and General Purpose Input (GPI) signals.
1
4
2
3
PIN
SIGNAL
1
GROUND
2
SS/GPI
3
TIMECODE
4
GENLOCK
NOTE: Mating connector is FGG.00.304.CLAD27Z.
SYNC TRIGGER BUTTON CIRCUIT
The SYNC connector has a 3.3 V Schmitt trigger (5 V tolerant). The trigger is not a switch closure circuit, so it
requires that the trigger source supplies current. Both edges of the input signal may be used as a trigger.
For example, this is the behavior of the circuit when the GPI trigger is used for record start/stop:
 Start Record: On ground to 3.3 V transition
 During Record: Hold at 3.3 V
 Stop Record: On 3.3 V to ground transition
 During Stop: Hold at ground
100 ohm
1/4 W
Input Voltage:
3.3 V to 5.0 V
Batteries:
2x AA or AAA
3x AA or AAA
NOTE: In the diagram above, values are approximate. Use standard values.
COPYRIGHT © 2015 RED.COM, INC
4-PIN 00B LEMO SYNC CONNECTOR
DESCRIPTION
Common ground
Shutter sync/general purpose input trigger
SMPTE unbalanced timecode input
Tri-level sync input
Push to make/break
button/toggle
1.7 V, 20 mA
On when output
signal is high
electrolytic
68 ohm
1/4 W
Front Face of the SYNC (Video Sync)
Connector (Looking at the DSMC)
Female
BNC
10 uF
10 V min.
DIRECTION
N/A
In
In
In
Trigger Button
Circuit Diagram
955-0020_V6.0, REV-D |