Incorrect Color Temperature - RED EPIC-M DRAGON Operation Manual

Hide thumbs Also See for EPIC-M RED DRAGON:
Table of Contents

Advertisement

R E D D S M C O P E R AT I O N G U I D E

INCORRECT COLOR TEMPERATURE

SYMPTOM
The camera color temperature is off and the image looks warmer or cooler than normal.
POTENTIAL RESOLUTIONS
 Perform an auto white-balance. For more information, go to
 Perform a black shade calibration. For more information, go to
 If you have the DSMC Interchangeable OLPF system installed, verify that you have the correct OLPF
selected in the OLPF menu. For more information, go to
TIMECODE OR GENLOCK DOES NOT FUNCTION
SYMPTOM
The SYNC, GEN, and/or TC light is red, yellow, or grayed out.
POTENTIAL RESOLUTIONS
 Ensure your timecode or genlock device is compatible. For more information, go to
on page
169.
 Use a different cable.
 Ensure your timecode or genlock device settings match your project settings.
 Ensure your timecode or genlock device is set to the correct source. For more information, go to
External Timecode" on page 158
 Ensure that your Sensor Sync Mode is set to Genlock. For more information, go to
160.
 If you are using an Ambient device, set the ACN (Ambient Clockit Network) to Off.
COPYRIGHT © 2015 RED.COM, INC
"Verify Installed OLPF" on page
or
"Genlock" on page
159.
"Color Temperature" on page
"Calibrate" on page
107.
"Sensor Sync" on page
955-0020_V6.0, REV-D |
81.
45.
"Compatible Devices"
"Set Up
179

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents