Garmin Apollo CNX80 Installation Manual page 115

Hide thumbs Also See for Apollo CNX80:
Table of Contents

Advertisement

APPENDIX A - C
A.1 E
NVIRONMENTAL
The Apollo CNX80 has been tested to the following environmental categories per procedures defined in
RTCA/DO-160D. Tests were conducted from September 2002 to April 2003 using the original 1997 revision of
DO-160D and specification defined in PD3107.
Nomenclature: CNX80
Part No.:
430-6100-8xx-xxx
TSO No.:
C34e, C36e, C37d, C38d, C40c, C113,
C128, C146a
Conditions
Temperature and Altitude
Temperature Variation
Humidity
Operational Shocks and Crash Safety
Vibration
Explosion Proofness
Waterproofness
Fluids Susceptibility
Sand and Dust
Fungus Resistance
Salt Spray
Magnetic Effect
Power Input
Voltage Spike
Audio Frequency Conducted Susceptibility -
Power Inputs
Induced Signal Susceptibility
Radio Frequency Susceptibility (Radiated and
Conducted)
Emission of Radio Frequency Energy
Lightning Induced Transient Susceptibility
Lightning Direct Effects
Icing
Electrostatic Discharge (ESD)
Remarks:
[1] Operation at 55,000 feet verified for 30 minutes following decompression.
[2] Also passed Category P In Flight Loss of Cooling (180 min at +30 °C) with internal fans not operating.
• Passed the Thermal Shock test (+55C to -20C in < 20 sec) required by TSO C113 (per AS8034 paragraph 5.23).
• Passed the Operating Overpressure test (170 kPa) required by TSO C113 (per AS8034 paragraph 5.2.5).
• Passed GPS L1 Radiated Susceptibility test (20 mV/meter) required by TSO C146a (per DO-229C para 2.4.1.2.3).
Apollo CNX80 Installation Manual
ERTIFICATION
Q
UALIFICATION
Environmental Qualification Form
Manufacturer:
Section
Equipment tested to Category C1 & A1
4
Operating temp: -20ºC to +55ºC
Short time high temp: to +70ºC
Ground survival temp: -55ºC to +85ºC
Altitude: 35,000 feet
Decompression: 55,000 feet [1]
Overpressure (non-operating)
No external cooling required provided internal fans are
5
Equipment tested to Category C, 2°C/min
6
Equipment tested to Category A, standard humidity
environment
7
Equipment tested for both operational and crash safety shocks
to Category B Type 5R
Equipment operated normally after crash shocks.
(20 Gs at 11 msec (impulse) and 3 sec (sustained))
8
Equipment tested without shock mounts to Category S (Curves
B, M) and Category U (curves F, F1)
9
Equipment identified as Category X, no test required
10
Equipment identified as Category X, no test required
11
Equipment identified as Category X, no test required
12
Equipment identified as Category X, no test required
13
Equipment identified as Category X, no test required
14
Equipment identified as Category X, no test required
15
Equipment is Class Z (Dc is at 0.185 meters)
16
Equipment tested to Category A & B (14 and 28 VDC system)
17
Equipment tested to Category A
18
Equipment tested to Categories A & B
19
Equipment tested to Category C
20
Equipment tested to Category VV- (Category V Conducted,
Category V Radiated. No Pulsed test performed.)
21
Equipment tested to Category M
22
Equipment identified as Category A3 B2
23
Equipment identified as Category X, no test required
24
Equipment identified as Category X, no test required
25
Equipment tested to Category A
560-0982-00 Rev D
Appendix A - Certification Data
D
ATA
Garmin AT
2345 Turner Road SE
Salem, Oregon 97302
Description of Conducted Tests
unobstructed and operating. [2]