To Remove The Burner Only; To Remove The Complete Burner Module, Pipes And Pilot - Valor BLACK BEAUTY 348 Installer And Owner Manual

Radiant / convector gas fire
Table of Contents

Advertisement

12.6 To remove the burner only.

1. Remove the fascia as section 12.2.
2. Isolate the gas supply.
3. Detach and remove the upper and
lower injector pipes. Do NOT hold the
pressure test point connector as this may
cause damage.
4. Unscrew and remove the two screws
that secure the pilot unit to the burner.
5. Remove the battery from the
electronic igniter unit.
6. Detach the left end of the burner
module from the radiant box by removing
one screw and a wing nut (See figure
15).
7. Carefully slide the burner module to
the right to free it from the right side of
the radiant box (See figure 15).

12.7 To remove the complete burner module, pipes and pilot.

1. Remove the fascia as in section 12.2.
2. Isolate the gas supply.
3. Remove the battery from the electronic ignition unit.
4. Support the inlet 'T' connector to avoid straining the pipework and disconnect the
appliance.
5. Disconnect the slider control by removing the knurled screw from the connector
arm. Rotate the control pivot bracket fully anticlockwise.
6. Make a note of where the igniter unit leads are located, then remove the two
microswitch leads and ignition lead from
the igniter unit; pull the tags and not the
leads as this may cause damage.
7. Unscrew and remove the three screws
from the rear of the assembly (See figure
16).
8. Detach the left end of the burner
module from the radiant box by removing
one screw and a wing nut (See figure
15).
9. Lift the slider arm and carefully slide
the burner module to the right to free it
from the right side of the radiant box
(See figure 15).
10. Replace in the reverse order.
©
GDC Group Ltd. 2011
INSTALLER GUIDE
Page 27
Figure 15. Burner module removal
Figure 16.

Advertisement

Table of Contents
loading

Table of Contents