Servicing And Parts Replacement; To Replace Radiant(S) - Valor BLACK BEAUTY 348 Installer And Owner Manual

Radiant / convector gas fire
Table of Contents

Advertisement

12. SERVICING AND PARTS REPLACEMENT

Always turn off the gas supply and allow the appliance to cool completely
before commencing any servicing (The appliance inlet "T" connector
incorporates an isolating valve).
It is recommended that, at least once a year, the appliance is disconnected
and the catchment space behind the closure plate checked and cleared of
any debris. The closure plate must be resealed to the wall after checking.
Check that soot or debris is not impairing the electrode spark or pilot burner.
Check that soot or debris is not blocking any of the holes in the main burner.
Always test for gas soundness and spillage after servicing the appliance.

12.1 To replace radiant(s).

Always use the correct type of replacement radiant. Ask for Valor part number
5132071 (Single Radiant).
Remove the dress guard by pressing down the two hooks at the top. Tilt the guard
forward and lift out (See figure 14).
Lift the radiant upward to clear the metal retaining bar then pull out bottom first.
Fit the new radiant by inserting its top under the top lip of the radiant box then
swing the bottom of the radiant over and behind the retaining bar. It is important
that that the rear face of the radiants rest against the horizontal ribs in the
rear panel. There will be a small gap between their bottom front edges and
the retaining channel at the front of the radiant box.
Figure 14. Replacing radiant(s)
©
GDC Group Ltd. 2011
INSTALLER GUIDE
Page 25