Gas Consumption; Appliance Dimensions And Clearances - Valor BLACK BEAUTY 348 Installer And Owner Manual

Radiant / convector gas fire
Table of Contents

Advertisement

OWNER GUIDE
Do provide a minimum clearance of 100mm between the fascia sides and any corner
wall having combustible material or other combustible surface which projects beyond
the front of the fire (See figure 2). Please bear this in mind if ever you are considering
altering the room.
Don't hang clothing, towels or any other fabrics over the fire.
Don't fill in the space behind the fascia.
Don't use the fire without the dress guard being in position.
Don't attempt to clean or service the fire until it has been switched off and allowed to
cool completely.
Don't use the fire with damaged radiants.

GAS CONSUMPTION

Has a maximum natural gas input of 5.4 kW (Gross)
Has a maximum natural gas output of 4.0 kW
Has a minimum natural gas input of 2.7 kW (Gross)
Has a minimum natural gas output of 1.85 kW

APPLIANCE DIMENSIONS AND CLEARANCES

Figure 2. Dimensions and clearances
Page 34
©
GDC Group Ltd. 2011