      DANGER!  ELECTRICAL SHOCK HAZARD.  
Only qualified personnel who have read and understand this entire manual should attempt to install, 
or service this unit, failure to do so could result in death or serious injury.  DO NOT plug into an 
electrical supply until specifically instructed.  
 
 
       WARNING!  ALWAYS SANITIZE BEFORE USE. 
 Sanitize before use to eliminate any potential microbiological contaminates.      
 
Materials Needed:  
 
 Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear  
 Phillips Screwdriver.   
 Temperature Gauge. 
 Water Pitcher or Container to collect water from the faucet 
 5‐gallon container or drain basin 
 Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner 
 ¼" Plastic Tubing, at least 4 feet in length, and assorted ¼" quick connect fittings. 
 TDS Meter and Test Strips for measuring chlorine. ‐ Optional 
 1/8 NPT Female Thread to ¼" Compression Fitting (Used to connect hose to drain fittings) 
 
 
1. Unpack the Waterlogic WL500 Water Treatment System and check exterior for damage. 
 
    
WARNING!  WL500 WATER TREATMENT SYSTEM IS HEAVY. 
Use proper lifting aids and handling techniques to avoid injury.  Use assistance as single person 
lift could cause injury. Always drain before handling and transporting and handling to reduce the 
weight of the unit.   
   
2. Remove the Retaining Screw that is located directly in front of 
the faucet nipple.  Refer to Figure 1.  Removing this screw will 
allow access to the inside serviceable components (Filters and 
UV Lamp). 
 
3. Open the Front Hatch Cover by lifting up and hinging outward.  
Front Hatch Cover can be removed by carefully squeezing Panel 
base and pulling over Hinge Pins. 
 
Flush Filters 
 
      CAUTION!  FILTERS FLUSH REQUIRED. 
 
WL500 Water Treatment Systems are not supplied with Filters.  Filters should be configured to 
optimize your system.  Filters need to be configured and specified to do the job given the local water 
conditions, usage, maintenance schedule, and placement restrictions. 
  
 
 
 
 
 
 
 
 
 
WL500 Manual 
PRE‐INSTALLATION PROCEDURES 
                                                                           Page 54   Revision 4‐10‐2019 

Advertisement

loading
Need help?

Need help?

Do you have a question about the WL500 and is the answer not in the manual?

Questions and answers

Summary of Contents for WaterLogic WL500

  • Page 1 Materials Needed:      Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear    Phillips Screwdriver.     Temperature Gauge.   Water Pitcher or Container to collect water from the faucet   5‐gallon container or drain basin   Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner   ¼” Plastic Tubing, at least 4 feet in length, and assorted ¼” quick connect fittings.   TDS Meter and Test Strips for measuring chlorine. ‐ Optional   1/8 NPT Female Thread to ¼” Compression Fitting (Used to connect hose to drain fittings)      1. Unpack the Waterlogic WL500 Water Treatment System and check exterior for damage.         WARNING!  WL500 WATER TREATMENT SYSTEM IS HEAVY.  Use proper lifting aids and handling techniques to avoid injury.  Use assistance as single person  lift could cause injury. Always drain before handling and transporting and handling to reduce the  weight of the unit.        2. Remove the Retaining Screw that is located directly in front of  the faucet nipple.  Refer to Figure 1.  Removing this screw will  allow access to the inside serviceable components (Filters and  UV Lamp).    3. Open the Front Hatch Cover by lifting up and hinging outward.  ...
  • Page 2 Sanitize using a household bleach solution or other approved cleaner throughout the cold and sparkling  water circuits.  Follow all instructions on the sanitizer and flush with fresh water through the faucet  until odor and taste is acceptable.           WARNING!  USE PROPER PERSONAL PROTECTIVE EQUIPMENT  Always ensure proper ventilation and use proper personal protective equipment such as gloves and  eye protection when using chemicals.  Refer to Material Safety Data Sheet for specific requirements  of each chemical product. Take all necessary precautions to prevent sanitizer from contacting eyes,  clothing, and any other surfaces in could damage (carpets).      6. Remove the UV Cover Plate and set aside – 2 Screws.    7. Disconnect the UV Lamp harness and carefully remove the UV Lamp from the Quartz Sleeve.    CAUTION!  UV SYSTEM IS FRAGILE. Never handle the UV System with bare hands.  UV Lamp and  Quartz Sleeve must be free of oils and contaminants to ensure proper operation.      8. Remove UV Sensor from the side of the Cold Tank/Quartz Sleeve Retaining Cap.    9. Unscrew Cold Tank/Quartz Sleeve Retaining Cap and remove the Quartz Sleeve.  This may require  Top Cover to be removed to access properly and facilitate removal.    10. Mix ½ gallon of sanitizer per directions or use Bleach Solution (1 teaspoon = 1/6 oz. = 5 ml = ½ cap  full) of household bleach (Sodium Hypochlorite 5 ‐ 10% Concentration) with 1/2 gallon of water.   Always ensure sanitizer is compatible with stainless steel and acetyl plastic.    11. Pour sanitizer solution into Cold Tank thru funnel or spout.  You may add concentrated sanitizer (½  cap bleach) directly into empty Cold Tank instead of premixing.           WL500 Manual                                                                             Page 55   Revision 4‐10‐2019 ...
  • Page 3   14. Connect 40‐60 psi regulated, potable water supply to the water inlet bulkhead fitting located on the  back of the unit.  Turn on water supply and check for leaks.    15. Connect CO  gas line to WL500 Water Treatment System Bulkhead Inlet Fitting.  Regulate to 35‐45  psi.  Turn on CO .    WARNING! HIGH PRESSURE CO  GAS. Use/Handle in accordance with all safety standards.                 DANGER!  ELECTRICAL SHOCK HAZARD.   Do not plug in unit unless qualified.  Only qualified personnel who have read and understand this  entire manual should attempt to install or service this unit.      GREEN                      RED    16. Connect WL500 Water Treatment System to power, and turn on the RED  Power Switch I=ON.           CAUTION!  NEVER TURN ON HEATER BEFORE FILLING HOT TANK.  GREEN Compressor/Heater Switch must be in the O=OFF position while  the Hot Tank is empty.  Damage could occur within one minute and the overload (high limit) will  require manual reset if heater is turned on with an empty Hot Tank.     Fill the Cold Circuit with Sanitizer    17. Wait 10 seconds for the unit to perform its diagnostics checks, depress the main dispensing button  on the front control Panel until cold water/sanitizing solution comes out the faucet.      NOTE:  Container and drain basin will be required to catch the water from the faucet.      WARNING!  Use Personal Protective Equipment.  Gloves and Eye Protection Required.  The first 2  or 3 gallons of water will contain concentrated sanitizer. Use extreme care!    ...
  • Page 4  F   Water in the hot circuit is not sanitary until the temperature over 171 F for 5 minutes.  Do Not Ingest and avoid contact until heater is turned on for at least 5 minutes.    UV System Functional Test    WARNING!  ULTRAVIOLET RADIATION.  Protect your skin and eyes against ultraviolet rays.   Never look directly at an operating UV light.  Disconnect before removing.    24. Dim or shield the overhead lights and peer into the machine, on top of the Cold Tank, at the UV  connector and Retaining Cap.  The blue glow indicates that the lamp is lit.    25. Find the white wires delivering power to the top of the lamp assembly.  Follow the wires back until  the electrical connector is found.  Disconnect the electrical connector and verify that the UV Lamp  alarm annunciates.      26. Reconnect the UV Lamp wire connector, and cycle the Red Power Switch to clear the alarm.    Compressor Test       GREEN                      RED  27. Switch on the GREEN Compressor / Heater Switch (I=ON).  Always ensure  tanks are full of water before turning on the heater or the overload (high  limit) will open and require manual reset.  Once the Compressor starts, the  fan condenser also will start.  Verify the fan has started by feeling for the  discharge of air at the rear grill of the machine.  Heat exchange is a signal  that the refrigeration system is working.    28. Monitor the Cold Tank temperature on the front display of the unit by changing the Temp Display to  RANGING.  It will take about 45 minutes for the unit to chill down to the default set point  temperature of 41F assuming ambient inlet water of 75 F.  WL500 Manual                                                                             Page 57   Revision 4‐10‐2019 ...
  • Page 5 29. Once the machine reaches its target temperature, the Compressor and fan will shut off.  Draw a  glass of cold water and verify it is has been chilled to proper temperature.    Heater Test    30. Always ensure tanks are full of water before turning on the heater or the overload (high limit) will  open and require manual reset.  It will take the heater approximately 10 minutes to heat the water  from ambient 75F to the factory set point of 189F.  You can monitor the Hot Tank temperature by  selecting the hot button when the Temp Display is RANGING.  Dispense a cup of hot water to ensure  the temperature/odor/taste is acceptable.    WARNING!  VERY HOT WATER CAN BURN OR SCALD.   Hot water should be dispensed carefully into insulated container to avoid injury.     Drain the WL500 Water Treatment System for Transport    31. Drain the WL500 Water Treatment System for transportation per the Draining Instructions in this  manual.           WARNING!  STORE UNIT EMPTY.  ALWAYS SANITIZE BEFORE REUSE.  The unit must be completely drained and sealed before storing to avoid stagnation and reduce  microbiological contamination (potential bacterial growth).    WL500 Manual                                                                             Page 58   Revision 4‐10‐2019 ...
  • Page 6    Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear    Phillips Screwdriver.     Temperature Gauge.   Water Pitcher or Container to collect water from the faucet   5‐gallon container or drain basin   Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner   ¼” Plastic Tubing, at least 4 feet in length, and assorted ¼” quick connect fittings.   TDS Meter and Test Strips for measuring chlorine. ‐ Optional   1/8 NPT Female Thread to ¼” Compression Fitting (Used to connect hose to drain fittings)        1. Unpack the Waterlogic WL500 Water Treatment System and check exterior for damage.         WARNING!  WL500 WATER TREATMENT SYSTEM IS HEAVY.  Use proper lifting aids and handling techniques to avoid injury.  Use assistance as single person  lift could cause injury. Always drain before handling and transporting and handling to reduce the  weight of the unit.        2. Remove the Retaining Screw that is located directly in front of  the faucet nipple.  Refer to Figure 1.  Removing this screw will  allow access to the inside serviceable components (Filters and  UV Lamp).    3. Open the Front Hatch Cover by lifting up and hinging outward.  ...
  • Page 7: Drain Line

    Sparkling Water Level Sensor Level Sensor Fitting and Probe 6. Remove Fitting from CO  Line    7. Attach Water Inlet Valve     8. Add 1‐2 drops of Bleach into the Sparkling Tank through the  Sparkling Water Level Sensor line.        9. Connect Drain Water line and fitting to the Sparkling Water  Level Sensor line.  Drain Line   10. Flush 3‐5 Gallons through Sparkling Tank.  There  should be no bleach smell after flushing.    11. Reconnect Sparling Water Level Sensor, Fitting and Wires.            WL500 Manual                                                                             Page 60   Revision 4‐10‐2019 ...
  • Page 8 WL500 DRAINING INSTRUCTIONS            WARNING!  WL500 WATER TREATMENT SYSTEM IS A HEAVY OBJECT.  Use proper lifting aids and handling techniques to avoid injury.  Use assistance as single person lift could  cause injury. Always drain before handling to reduce weight.      Draining Notes    There are 3 tanks and a booster pump circuit that must be drained in the WL500 Water Treatment  System.  The cold still water circuit of the WL500 Water Treatment System consists of a 2‐liter Cold  Tank, a 1‐liter pre‐chill chamber and a booster pump circuit that is sealed and must be vented to drain.   The booster pump will have some water in the circuit that must be purged to remove it.  The Sparkling  Chamber does not have a vent or drain port and must be dispensed until empty (pushing CO  gas only  out of the faucet) to clear the water from the Sparkling Chamber.  It is critical to clear the cold still  water before draining the Sparkling Chamber to ensure the pump does not inject water back into the  Sparkling Chamber.  The Hot Tank has a drain port and is the only tank that is open to atmosphere  through the vent and faucet.     GREEN                      RED    Prior to draining the Hot Tank, turn the GREEN Compressor/Heater Switch off  (O=OFF), and dispense 2 liters of hot water from the machine.  As hot water is  dispensed from the faucet of the unit, colder water will be introduced into the Hot  Tank.  Since the GREEN Compressor/Heater switch is turned off the heater will not  energize and heat the incoming tap water.  Following this precaution prevents  exposing personnel and equipment (drains, catch basin, etc.) to scalding hot water.     Disable Cold and Hot Tanks       GREEN                      RED  1. Turn off the GREEN Heater / Compressor Switch to disable the heater and  Compressor. O=OFF    2. Dispense 2 liters of water through the Hot Tank to cool the water temperature in  the Hot Tank and avoid burns.           WARNING!  VERY HOT WATER CAN BURN OR SCALD. ...
  • Page 9 9. Unplug the UV Lamp and remove UV Lamp.    10. Remover the UV indicator sensor from the Quartz Sleeve retaining nut.    11. Unscrew the Quartz Sleeve retaining nut and remove Quartz Sleeve to vent the cold circuit.    12. Remove the Cold Tank drain line cap and drain the 2 liters into a container.      13. Remove the pre‐chill drain line cap and drain the 1 liter of water from the pre‐chill chamber and the  booster pump circuit.    14. A total of 3 liters of cold still water will drain from the unit.    Drain the Sparkling Water Chamber    15. Dispense all sparkling water out of the Sparkling Chamber through the faucet of the WL500 Water  Treatment System into the drip tray (holds 1.5 liters) or other container until only CO  gas is  dispensed.  The Sparkling Chamber holds a maximum of 1 liter of water.    16. Release the dispense button and let the booster pump cycle on to inject any remaining water from  the still water feed circuit and pump into the Sparkling Tank for 30 seconds.    17. Dispense sparkling water to clear any remaining water from the Sparkling Tank through the faucet  until only CO  gas is coming out.     GREEN                      RED    18. Turn off the RED Power switch (O=OFF).  This will kill power to the pump  ensuring that no water is injected back into the Sparkling Chamber and shut ...
  • Page 10 25. Drain 1.6 liters of hot water into suitable container.      Reassemble the Unit    26. Reinstall all drain caps.    27. Reinstall the Quartz Sleeve.    28. Reinstall the Quartz Sleeve Retaining Cap firmly.  Do not over tighten O‐ring seal.    29. Reinstall the UV Lamp.  Be careful not to touch UV Lamp surface as oils from your hands can cause  dark spots and impact the performance of the system.  Always wipe off lamp with alcohol wipe or  equivalent if needed.  Ensure lamp wires are not crossed and never force lamp into the sleeve to  avoid damage.    30. Reconnect UV Lamp.    31. Reinstall the UV sensor into the Retaining Cap.      32. Reinstall top cover and the UV Lamp cover plate.    33. Ensure the front display PCB ribbon connectors are securely attached and completely seated to  avoid problems.    34. Close front Hatch Panel and tighten the locking screw to secure.      WL500 Manual                                                                             Page 63   Revision 4‐10‐2019 ...
  • Page 11 WL500 QUICK START INSTALLATION GUIDE    Critical Requirements    Establish Food Grade CO  Supply and regulate to 35‐45 psi. This will produce optimum sparkling water     and CO concentration when combined with 46 F degree or cooler water.  Regulate the Water Supply to  2  40–60 psi.  ALWAYS use a pressure regulator and leak protection when installing units.     1) Prior to setting up the WL500 Water Treatment System machine, open the knock‐out on the back  panel of the base cabinet to allow routing of the CO pipe if using the base cabinet.   2    2) Unpack the WL500 and set on top of countertop or base cabinet so that the side panels of the  machine align with the side panels of the base cabinet.    3) Secure the WL500 to the base cabinet using the bolt provided in the  base cabinet.  Note that the connection point is accessed from the  underside of the base cabinet.   The bolt threads into the WL500 base  plate and locks the unit together.     4) Install a regulator onto a 5lb or 10lb food grade CO  bottle and purge  some gas from the bottle.  Regulate output to 35‐45 psi.  Close the  regulator outlet valve, and secure in place.     5) Route a ¼‐inch pipe from the outlet fitting of the CO regulator  2 ...
  • Page 12: Installation Procedures

      WARNING!  USE ONLY Waterlogic SUPPLIED POWER CORD (WLCP PN 10‐3007).  Locate system  within 5 feet of power supply.  Never use an extension cord or adapter.  Do not use a damaged  power cord or plug.  Keep power cord out of heavy traffic areas and away from heat sources.  Do  not, under any circumstances, remove ground prong or alter the power cord.  Never pull the power  plug from the outlet with a wet hand or allow the plug to get wet.  Failure to use the supplied power  cord will void UL Certification and Warranty.      CAUTION!  INDOOR USE ONLY.   Never exposed to direct sunlight, heat sources, or ambient air  temperature above 97°F (36°C) or below 50°F (10°C).  Install indoors and keep unit away from  excessive humidity.  Never expose to freezing temperatures.  Ensure there is adequate clearance  around the unit to allow refrigeration system condenser to dissipate heat.  Warmer environments  require more clearance around the unit.  Minimum clearance around all surfaces of the machine is 2‐ inches.  Installs where the ambient temperature exceeds 80°F, require a minimum of 4‐inches  clearance for proper heat dissipation and efficient operation.       CAUTION!  USE A WATER PRESSURE REGULATOR. Waterlogic will not be responsible for injury or  damage caused by excessive water pressure.  Operating pressure must be 40 psi to 60 psi.  Be aware  any of potential pressure surges caused by building/municipal pumping stations.      CAUTION!  USE UV STABILIZED SUPPLY LINES.  Feed the unit with a potable ambient or cold‐water  supply only.  Feed water over 105° F (40°C) can damage the treatment components.  Water block  devices and external leak detectors are strongly recommended. Locate the unit as close to the water  supply and the electrical connections as possible.             WARNING!  HIGH PRESSURE CO  GAS.  Use/Handle in accordance with all safety standards.           WARNING!  STORE UNIT EMPTY.  ALWAYS SANITIZE BEFORE USE.  The unit must be completely drained and sealed before storing to avoid stagnation and reduce  microbiological contamination (potential bacterial growth).  Sanitize before use to eliminate any  potential microbiological contaminates     WL500 Water Treatment System can be combined with RO Filtration Systems.  RO will require a drain  connection.  Refer to all applicable plumbing codes and standards in your area for these requirements  (air gap connections and back flow prevention may be necessary).  WL500 Manual                                                                             Page 65   Revision 4‐10‐2019 ...
  • Page 13 Pre‐installation and sanitization procedures as prescribed in this manual must be performed before  installing the WL500 Water Treatment System.    Always install indoors and place the Waterlogic WL500 Water Treatment System on a firm, flat and  stable surface.        Attach the water supply line to the 1/4” feed water inlet bulkhead fitting on the back of the unit.   Waterlogic requires the use of a water pressure regulator.  Water feed pressure must be between 40‐ 60 psi.   Turn on the water supply and check for leaks.         GREEN                      RED    1. Check to ensure that both the RED Power Switch and the GREEN Heater /  Compressor switches are in the O=OFF position.  NOTE:  Switches have internal  LED that illuminates when placed in I=ON position.     2. Connect the power cord to the back of the Waterlogic WL500 Water  Treatment System and to a 120 Volt supply.       GREEN                      RED  3. Turn the RED Power Switch to I=ON position.             CAUTION!  NEVER TURN ON HEATER BEFORE FILLING HOT TANK.  GREEN Compressor/Heater Switch must be in the O=OFF position while the Hot  Tank is empty.  Damage could occur within one minute and the overload (high  limit) will require manual reset if heater is turned on with an empty Hot Tank.     4. Prime the Cold Circuit.  Holding a container under the dispensing faucet, press and hold the main  dispensing button until a continuous flow of water is obtained.  Once a continuous flow is obtained,  release the dispensing button.  Cold Tanks are now full.      5. Prime the Hot Tank.  Holding a container under the dispensing faucet, press the hot button (Button  3) followed by the main dispensing button until a continuous flow of water is obtained.  Once a  continuous flow is obtained, release the main dispensing button.  Hot Tank is now full.    ...
  • Page 14 9. Move the Waterlogic WL500 Water Treatment System into its final operating position.  Be sure that  a minimum of 2” clearance is maintained around both the sides and the back of the unit.  This is  important to allow proper airflow and heat exchange of refrigeration system.     10. Level unit using the adjustable feet to level if necessary.  Never install on incline.      GREEN                      RED    11. Turn the GREEN Heater / Compressor switch on I=ON.  Check for fan and  Compressor operation.  This can be done by listening to the unit when the  GREEN Heater / Compressor switch on I=ON and/or is turned on and/or visibly  checking the fan.  All tanks must be full.    12. Change the Temp Display to Ranging to monitor the cold and hot water temperatures in the tanks.   After 15 minutes, the cold‐water should drop approximately one degree every 1‐1/2 minutes.  The  hot water will heat rapidly and should reach set point in 10 minutes.    13. When the unit has reached its Hot Temp Set Point, the heater will cycle off.   When the unit has  reached its Cold Temp Set Point Temperature, the Compressor will cycle off.    14. Once the unit is at the target temperature(s), sample the water to ensure water meets expectations  and additional rinsing or adjustment is not required.     15. Regenerate the sparkling water by dispensing until a continuous flow of gas is obtained and release  to let the pump inject cold‐water (below 7.7°C / 46° F) into the chamber.  This provides Premium  Sparkling Water.  Sample the sparkling water to ensure it meets expectation.     16. Check the unit for any leaks.  External Leak Protection is always recommended.    17. If you choose, reconfigure the temperature display back to the original Static setting and   Verify Default Program Settings (refer to Programming Instructions): ...