Setup Sheet Calibration

This calibration calibrates the power of the LED situated on the cartridge carriage, for better
scanning of the setup sheet.
Perform the setup sheet calibration whenever:
D The EEROM is cleared
D The cartridge carriage is replaced
D The optical sensor on the cartridge carriage is replaced
D Problems frequently occur with setup sheet scanning
To calibrate the LED, perform the following procedure:
1 Enter service mode D page 7 2.
2 Load a blank sheet of paper.
o not use vellum, transparent or polyester media, or recycled paper.
3 Hold down the
key and press
ALT
The plotter positions the cartridge carriage over the media. The carriage remains
there for about 1 minute with the red L
calibration. The plotter then ejects the sheet.
To verify that the calibration has been performed correctly, plot a service configuration
plot, D page 8 23, and look at the field entitled Setup Sheet LED Calibration formula."
A formula appears in this field. If the calibration has not been performed correctly, a
message, saying that the LED has not been calibrated for setup sheet, appears.
7 10 Calibrations
.
Setup-Sheet Calibration
lit, while the plotter performs the
ALT
Setup-Sheet
Calibration
C3187 90000