* M4: Fuser belt, M5: Heat roller, M6: Fuser roller
When any or all of fuser belt, heat roller and fuser roller is replaced or taken off from the fuser
unit, perform adjustment for the separation plate gap.
P.3-76 "3.11 Adjustment of the Separation Plate Gap"
* M8: Fuser belt front thermistor
Clean the thermistor with alcohol if the toner or dirt is sticking to it when the fuser belt is replaced.
Do not deform or damage the thermistor during the cleaning. Replace the thermistor with a new
one if it is damaged or deformed regardless of degree.
* M12: Fuser unit gear
Wipe off any old grease, and then apply 3 to 4 rice-sized grains of white grease (Molykote HP-
300) onto the gear teeth.
5.5.14

Exit unit

N2
Items to check
N1
Upper exit roller
N2
Lower exit roller
* N2: Lower exit roller
Wipe off any old grease, and then apply 0.5 to 1 rice-sized grains of white grease (Molykote HP-
300) onto the inside of the roller and both end faces of the shaft hole.
© 2008 TOSHIBA TEC CORPORATION All rights reserved
N1
Fig. 5-27
Lubri-
cation/
Cleaning
(x 1,000
Coat-
sheets)
ing
A
W2
5 - 27
Replacement
Opera-
tion
(x 1,000 drive
check
counts)
e-STUDIO2820C/2830C/3520C/3530C/4520C
PREVENTIVE MAINTENANCE (PM)
5
Parts
list
<P-I>
46-21
46-30

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio3530cE-studio4520cE-studio2830cE-studio3520c

Table of Contents