3.11 Adjustment of the Separation Plate Gap
Perform this adjustment when the following parts are replaced or disassembled.
Separation plate
Frame of fuser unit
Adjustment tool to use: Separation plate gap jig
Fuser belt
Heat roller
Notes:
•
Perform gap adjustment when the fuser unit is at a normal temperature.
•
Make sure that the pressure roller is released.
•
Be careful not to damage the fuser belt and jig (to protect the fuser belt, the jig is made from
ABS).
e-STUDIO2820C/2830C/3520C/3530C/4520C
ADJUSTMENT
Fuser belt
Heat roller
Separation plate gap jig
Separation plate
Fuser roller
Frame
Fig. 3-38
3 - 76
Fuser roller
0.6 - 1.0 mm
© 2008 TOSHIBA TEC CORPORATION All rights reserved