3.11 Adjustment of the Separation Plate Gap

Perform this adjustment when the following parts are replaced or disassembled.
Separation plate
Frame of fuser unit
Adjustment tool to use: Separation plate gap jig
Fuser belt
Heat roller
Notes:
Perform gap adjustment when the fuser unit is at a normal temperature.
Make sure that the pressure roller is released.
Be careful not to damage the fuser belt and jig (to protect the fuser belt, the jig is made from
ABS).
e-STUDIO2820C/2830C/3520C/3530C/4520C
ADJUSTMENT
Fuser belt
Heat roller
Separation plate gap jig
Separation plate
Fuser roller
Frame
Fig. 3-38
3 - 76
Fuser roller
0.6 - 1.0 mm