3.7.2
Belt tension adjustment of the Scan motor
(1)
Hook the belt tension jig to the motor bracket
and the flame.
(2)
Loosen screw-B and -C. (There is no need to
loosen screw-A, since it is a shoulder screw.)
(3)
The scan motor is pulled by the belt tension
jig. Fix screw-B and then -C at the stopped
position.
(4)
Remove the belt tension jig.
© 2008 TOSHIBA TEC CORPORATION All rights reserved
Pulley
Timing belt
Fig. 3-26
Belt tension jig
Fig. 3-27
e-STUDIO2820C/2830C/3520C/3530C/4520C
3 - 69
Belt tension jig
C
A
B
Scan motor
ADJUSTMENT