<Procedure>
Note:
Perform the adjustment while the TBU releasing lever is being pressed down after the installation
of the TBU.
(1)
Take off 1 ozone filter, 2 rear covers and the ozone exhausting duct.
(2)
Loosen 3 screws shown in the figure. (Tension is applied by the spring.)
(3)
Tighten the 3 screws loosened in step 2.
(4)
Reinstall the parts taken off in step 1.
© 2008 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2820C/2830C/3520C/3530C/4520C
3 - 75
3