7. Configuration menu

CONFIGURATION
SPECIAL KEYS
ser. boiler press.
Group temp.
TURBOSTEAM
MEASUREMENT UNITS
N° ground
SOFTNER REGENER.
SPECIAL KEYS (not active) - The key can be personalized with one
of the following functions:
- II choice (second function, dispensing of a second beverage
- disable (disables key);
- stop.
Service boiler pressure – indicates the boiler pressure: 1.3 ÷ 1.4
bar (18 ÷ 20 psi)
Unit temperature – indicates the unit temperature, from 70 to 110
° C and from 158 to 230 ° F
TURBOSTEAM - includes 2 sub-menus
Stop steam temperature – indicates the automatic stop steam
temperature (Autosteam). Can be set between a minimum
of 40 and a maximum of 85° C (104 – 185 ° F).
Regolator - flow regolator: YES/ NO.
YES - the machine has the flow regolator on the
turbosteam circuit
NO - the machine does not have the flow regolator; is
therefore possible to set 4 different levels of emulsion.
See paragraph "Autosteam" on the following pages.
MEASURING UNIT – includes 2 sub-menus
Temperature – can be set to °C Celsius centigrade or °F Fahrenheit
degrees.
Pressure – can be set to bar or psi.
N. grounds – refers to number of grounds, from 0 (external
container) to 50.
REGENERATION - includes the parameters for the softner
regeneration: liters of resin (da 0,1l a 25l), hardness (da 0 a 45 °F)
CONFIGURATION
Custumer prog.
progr. block
Paym. system
Buzzer
WASHING OPTIONS
Standard data
DATA IN/OUT
Customer programming – YES/ NO
Programming block - programming block: YES/NO.
With the function active (YES) the use of the programming keyboard
is allowed with the technician card; "i" key remains always active.
Payment system – permits configuration of payment system,
when connected.
Buzzer - The machine buzzer can be enabled so that a beep is heard
+
when the keys are pressed.
u
1,4 bar
WASHING OPTIONS - See paragraph "Washing options" on the
070°C
following pages.
Standard data – loads standard data. YES/NO
030
DATA IN/OUT – contains three entries:
u
Key – indicates the key number from 0 to 60.
Data IN transfer from smart card to machine. OUT transfer from
machine to smart card.
TX/RX – to start data transfer
Archive reset – zeros the error log (Wash 1 Archive and
malfunctions archive) stored on the machine: YES/NO
.
MAINTENANCE - contains five entries to setting maintenance
parameters:
Max cycles - the number of cycles initially set: 40,000.
Max days - the number of days initially set: 185.
N° cycles - the number of cycles remaining before the next
N° days -
Reset -
+
u
NO
NO
OFF
YES
NO
u
CONFIGURATION
Archive reset
MAINTENANCE
maintenance session.
the number of days remaining before the next
maintenance session.
options are:
NO, countdown of cycles and days remaining
before the next maintenance session.
YES, the settings for number of cycles (40,000)
and remaining days (185) are reset
OFF, all controls for programmed maintenance
are disabled, and the "N. cycles" and "N. days"
counters are zeroed.