Jobs On Disk; Disk Encryption; Font Sharpening; Standby Disabled - Lexmark C920 Service Manual

Color laser printer
Hide thumbs Also See for C920:
Table of Contents

Advertisement

Jobs on disk

This setting only appears if there is a disk installed on the machine. Jobs on disk is used to delete buffered jobs
that are on the hard disk. This option appears even if there are no buffered jobs on the disk. The values for this
setting are delete and do not delete (default). Use the
the
key to accept the change.

Disk encryption

Disk encryption controls whether the printer encrypts information that is written to the disk. The setting only
appears if the hard disk is installed, and the 3-2 digits of config ID 2 are set to 01 (supported) or 10 (supported
with INA). The values for this setting are disable (default) or enable. Use the
desired value, and press the
Note: When disk encryption is changed, all information on the disk is destroyed. A prompt is displayed asking
for confirmation of the change before executing.

Font sharpening

Font sharpening allows a user to set a text point-size value below the high frequency screens used when
printing font data. For example, if the setting value is "24", all fonts sized 24 points or less use the high frequency
screens. To decrease the setting value by 1, press
Note: The font sharpening setting affects PostScript, PCL and XL.

Standby disabled

The value of this setting determines if the Standby Mode in the setup panel menu includes a "disabled" value. If
the value of this setting is "on", the "disabled" value appears in the Standby Mode menu. If the value of this
setting is "off", "disabled" doesn't appear. The values for this setting are on (default) and off. Use the
key to scroll to the desired value. Press the

Exit config menu

Pressing the
key to accept the change.
key while this option is selected restarts the printer into normal operating mode.
or
key to scroll to the desired value, and press
. To increase the setting value by 1, press
key to accept the setting.
5056-XXX
or
key to scroll to the
.
or
3-23